SPECIFICATIONS This battery powered sensor:

MOUNTING The base of the Sensor has 2 sets of holes: SAE 5 bolt hole For Plastic Tanks: Glue Sensor to top of tank. The SAE bolt holes form the basis for the bonding. Cable Length: No Cable. It is Battery powered and Bluetooth. Connections: No Connections Simple Calibrations: Calibration needed from Display Bluetooth Connection to Victron GX models ONLY Battery Life 3-5 years (longer range and lower level tank, battery life 3 years. Shorter range and tank level typically 50% then 5 year) Battery 2744 Bluetooth 5.3 Adv Output ONLY Deadband 30mm but this increases with the nominated tank depth below. Max Depth 200mm pre-set. User settings now set tank level at: 1) 0-500mm 2) 500-1000mm 3) 1000mm to 2000mm Repeatability 1mm Press button on top and reporting changes to 10 sec intervals for 10mins (during commissioning) After 10 mins at 10 sec reporting, interval changes to 60 second intervals

5.8mm 4.8mm

34mm

51mm

58mm

ETSI Safiery declares that this sensor is compliant with the European commission radio equipment directive 2014/53/EU article 3.1 and 3.2.

3