Safiery CANbus Alternator Controller

SCV; -- SYSTEM CONFIGURATION "SCV;, Lockout, BTS2ATS? , RevAmp, SvOvr, BcOvr, CpOvr, ,AltTempSet, drtNORM, drtSMALL, drtHALF, PBF, ,Amp Limit, Watt Limit, , Alt Poles, Drive Ratio, Shunt Ratio, ,IdleRPM, TachMinField, Warmup Delay, Required Sensor, DC_Disconnected_VBat, FeatureIN_mod, TriggerHalfPowerRPM, Ignore Sensor, Feature-OUT mod, , BMS Amp Cap ”

Lockout:

Current lockout level. (0..2), see $SCO: command.

0 or 1: Is BTS being used as 2 nd Alternator Temp Sensor? (1 = yes)

BTS2ATS?:

RevAmp:

0 or 1: Reverse polarity of Amp Shunt readings? (1 = yes)

System Voltage auto-detect (=0), or force (1.0x .. 4.0x  12v .. 48v)

SvOvr:

BcOvr:

Override Battery Capacity DIP switches (Dip 5/6). ( 0.00 = No)

CpOvr:

Override Charge Profile DIP Switches (Dip 2..4) (0 = No)

AltTempSet:

Target max running setpoint for Alternator, in degrees C

drtNORM:

Normal Amp reduction (de-rating) fraction

drtSMALL:

Amp reduction (de-rating) fraction when in SMALL - MODE

drtHALF:

Amp reduction (de-rating) fraction when in half-power mode.

PBF:

Pull-back factor, for reducing Field Drive at lower RPMs.

Amp Limit:

Defined Alternator size, or -1 to enable auto-sizing. Set this = 0 for installations where Alternator Sizing is not to be regulated (ala, battery focused installations). Note: During startup, and unless defined, this value will present: 1,000 Defined System size, or -1 to enable auto-sizing. Set this = 0 for installations where Watts loading is not to be regulated (ala, battery focused installations). Note: During startup, and unless defined, this value will present: 15,000

Watt Limit:

Alt Poles:

Number of poles on Alternator

Drive Ratio:

Ratio of engine and alternator drive pulley

Shunt Ratio:

Amp Shunt ratio in Amps / mV

IdleRPM:

Idle RPM value used as basis for Field Drive Reduction at lower RPMs.

TachMinField: Minimum % of field drive that will be applied if TACH MODE is enabled.