Safiery CANbus Alternator Controller

// - Device Priority

Relative ranking of DC charging Source

// - DC Voltage

0..3212.5v, in 50mV steps

// - DC Current

1600..+1512.5 in 50mA steps (0x7D00 = 0A)

// - Temperature

-40..210 in deg-C, in 1C steps

/***************************************************************************** // Charger Configuration Status - 1FFC6h // Input: // - Instance // - Charging Algorithm // - Controller Mode // - Battery Sensor Present // - Charger AC Line Line 1 or 2 (AC Chargers only) // - Battery Type // - Battery Bank Size 0..65,530 Ah, 1Ah increments // - Maximum charging current 0..250, 1A increments */ /***************************************************************************** // Charger Configuration Status2 - 1FF96h // Input: // - Instance // - Max Charge Current % // - Max AC current % Of attached line (AC Chargers only) // - Shore Breaker Size 0..250, 1A increments (AC Chargers only)

// - Default Batt Temp // - Recharge Voltage

0..3212.5v, in 50mV steps

*/

/***************************************************************************** // Charger Configuration Status3 - 1FECCh // Input: // - Instance // - Bulk Voltage 0..3212.5v, in 50mV steps // - Absorption Voltage 0..3212.5v, in 50mV steps

82

Powered by