Tomorrow’s Technology Today ™ METEOR BATTERY PARAMETERS
Safiery Meteor Lithium has these Compliance certificates IEC62619 – Certificate number: DK- 157722-UL Certificate is Issued in Denmark
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ METEOR BATTERY PARAMETERS
Data Cabling Pin Outs • CAN cabling Connection is standard NMEA compliant cable Isolated with no power to CAN. • 120 Ohm Precision resistor inside Meteor Lithium. • Any Battery can be a “master” • CAN connection is to Victron Cerbo VE.CAN. Set baud rate at 250baud. • A “blue” Victron CAN plug may be required if this is the only CAN connection. Connection of multiple batteries: • TcoankneetchteorN.eTghaetriveeisPolunglywOitNhEthceonMn5ecatvioiantitohnatcafibtsle. and connect to the “in” of the leading battery Positive Fuse Plug in the lower • Repeat this process for multiple trains of batteries till all connected. • Press the “Reset/On” button at the Master Battery. It will come on and then the string of connected batteries follows. • If there is a fault in the string or a connection is not screwed in properly, the Master will flash a red light. Remote On/Off/Reset • Connect an M3 cable to the top connector IN of the “Master” battery. • Pins are the connections to close with free voltage contacts to remotely turn on.
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ METEOR BATTERY PARAMETERS
Lithium 48V 2500Wh
Lithium 48V High Power 2000Wh
Sodium 48V 1700Wh
Lithium 36V 2400Wh
Lithium 24V 2500Wh
Cell Voltages as seen on Victron Display at Battery> Details
Cell over-voltage alarm
V
3.5V
3.5V
3.8V
3.5V
3.5V
Recovery voltage
V
3.4V
3.4V
3.6V
3.4V
3.4V
Cell over- voltage
Cell over-voltage protection
V
3.75V
3.75V
3.95V
3.75V
3.75V
Recovery voltage
V
3.6V
3.6V
3.7V
3.6V
3.6V
Cell low voltage alarm
V
2.7V
2.7V
2.0V
2.7V
2.7V
Cell low- voltage
Recovery voltage
V
2.9V
2.9V
2.35V
2.9V
2.9V
Cell low voltage protection
V
2.5V
2.5V
1.8V
2.5V
2.5V
Recovery voltage
V
2.7V
2.7V
2.2V
2.7V
2.7V
Note this Voltage is between 90-95% SOC
Balance on voltage
54.4
54.4
60
54.4
54.4
Auto Cell Active Balance
Voltage difference of Balance on mV Voltage difference of Balance off mV
mV
3
3
25
3
3
mV
2
2
15
2
2
Battery Voltages V
Low voltage charging prohibition for cell Battery over-volt alarm
THIS IS BMS LOCK OUT VOLTAGE
24
24
16
24
24
56
56
60.8
42
28
Recovery voltage
54
54
57.6
40.8
27
Battery over-volt
Bulk Charge = 58V, 62.8, 43.6, 28.6
Battery over-volt protection
58.4
58.4
63
43.8
28.8
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ METEOR BATTERY PARAMETERS
Lithium 48V 2500Wh
Lithium 48V High Power 2000Wh
Sodium 48V 1700Wh
Lithium 36V 2400Wh
Lithium 24V 2500Wh
Float Voltage = 54, 59.2, 40.8, 27 Cut Off Voltage Inverter = 45, 38, 36, 24 Recovery Voltage Inverter = 46.5, 40, 37, 25
Recovery voltage
54
54
59.2
40.8
27
Battery low-volt alarm
46.4
46.4
32
34.8
23.2
Battery low-volt
Recovery voltage
48
48
37.6
36
24
Battery low-volt protection
43.2
43.2
30
3.24
21.6
Recovery voltage
48
48
35.2
34.8
24
Charge over current alarm
Amps
55
150
50
55
100
Recovery
Amps
50
145
45
50
95
Charge over current
Nominal Power Max in Watts AT THE BATTERY
Watts
2,500W
7,250W
2,500W
2,000W
2,500W
Charge over current protection
Amps
60
160
60
60
110
Delay time
Amps
10s
10s
10s
10s
10s
Discharg over current alarm
Amps
55
155
50
65
105
Recovery
Amps
50
150
45
60
103
Discharg over current
Discharge over current protection
Amps
60
160
60
70
110
Delay time
Amps
10s
10s
10s
10s
10s
Peak current
Peak current
Amps
150A 30ms
300A 30ms
120A 30ms
150A 30ms
250A 30ms
Calculated Power in Watts AT THE BATTERY
Max 30mS (in rush current)
7,500W
15,000W
7,100W
5,750W
7,000W
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ METEOR BATTERY PARAMETERS
LED lamp sequence
1 operational light ,1 alarm light ,4 capacity indicator lights ● ● ● ●
●
●
SOC
ALARM
RUN
Capacity indication
Status
Status
Discharge
Capacity indicator
L4●
L3●
L2●
L1●
L4●
L3●
L2●
L1●
Solid Green Solid Green
0 ~ 25%
OFF
OFF
OFF
Flash
OFF
OFF
OFF
Solid Green OFF
Solid Green
25 ~ 50% OFF
OFF
Flash Solid Gree n Solid Gree n
OFF
The remaining capacity
Solid Gree n Solid Gree n
Solid Green OFF
Solid Green
Solid Green
50 ~ 75% OFF
Flash
Solid Green
Solid Green
Solid Green
Solid Green
Solid Green
≥75%
Flash
Running indicator light●
Solid Green
Flash
Light Blink explanation
Flash Mode
ON
OFF
Flash 1
0.25s
3.75s
Flash 2
0.5s
0.5s
Flash 3
0.5s
1.5s
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ METEOR BATTERY PARAMETERS
State indication
RUN
ALM
SOC
System state
Running state
Note
●
●
●
●
●
●
Shutdown
Sleep
OFF
OFF OFF
OFF OFF
OFF OFF
OFF OFF
OFF OFF
OFF
Standby
Normal
Flash1 Solid Green Solid Green
Standby status
Normal
OFF
According to battery indicator
Highest LED flash 2
Alarm
Flash2
According to battery indicator
Highest LED flash 2
Charge
overvoltage protection Temperature, overcurrent protection
Flash1
OFF
OFF
OFF
OFF
OFF
Flash1
Flash1 OFF
OFF
OFF
OFF
According to battery indicator
Normal
Flash3
OFF
According to battery indicator
Alarm
Flash3
Flash3
Stop discharging, forced dormancy without action after 48h when the mains is offline
Temperature, overcurrent, short circuit protection
Solid Green
Discharge
OFF
OFF
OFF
OFF
OFF
Under- voltage protection
OFF
OFF
OFF
OFF
OFF
OFF
Stopping Discharge
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6Powered by FlippingBook