Tomorrow’s Technology Today ™ SOLID STATE BATTERY PARAMETERS
Safiery Solid State Lithium has these Compliance certificates IEC62619 – Certificate number: 085-282360021-000 Certificate is Issued in Singapore
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ SOLID STATE BATTERY PARAMETERS
Data Cabling Pin Outs • Cc oAmNpclai abnl itncga Cb ol enInseocl taitoend iws si ttha nndoapr od wNeMr Et oA CAN. • 1St2a0teOLhimthiPurmec.ision resistor inside Solid • Any Battery can be a “master” • CV AE .NC Ac oNn. nS ee tc tbi oa nu di sr taot eVai ct t2r o5 n0 bCaeur db .o • Ai f t“hbilsu ei s” tVhiec torno lny CCAANN pcloungnme catyi obne. r e q u i r e d Connection of multiple batteries: • T“ oaukte” Mo f 8t ha ev ima tai os tne cr abbal tet ea rnyd wc oi tnhntehcet ot ot ht ehre ebnatdtecroyn.nect to the “In” of the second •
Repeat this process till all connected. • PB raet tses rtyh. eI t“ wR ei lsl ecto/mO ne ”obnuat nt odnt ahte tnhtehMe satsrtienrg of connected batteries follows. • Icfotnhneercet ii so na ifsa unlot ti ns ctrheewset dr i ni ng porroap e r l y , t h e Master will flash a red light. Remote On/Off/Reset • Connect an M8 cable to the IN of the “Master” battery. • Pins 7 and 8 are the connections to close with free voltage contacts to remotely turn on. • DO NOT CONNECT ANYTHING TO PINS 1-5 ON THIS CABLE.
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ SOLID STATE BATTERY PARAMETERS
Solid State Lithium 48V 2700Wh
Solid State Lithium 12V 2700Wh
Cell over-voltage alarm
V
3.5V
3.5V
Recovery voltage
V
3.4V
3.4V
Cell over- voltage
Cell over-voltage protection
V
3.75V
3.75V
Recovery voltage
V
3.6V
3.6V
Cell low voltage alarm
V
2.9V
2.9V
Recovery voltage
V
3.0V
3.0V
Cell low- voltage
Cell low voltage protection
V
2.5V
2.5V
Recovery voltage
V
2.7V
2.7V
Note this Voltage is between 90-95% SOC
Balance on voltage
3.4V
3.4V
Auto Cell Active Balance
Voltage difference of Balance on mV Voltage difference of Balance off mV
mV
30mv
30mv
mV
20mv
20mv
Low voltage charging prohibition for cell Battery over-volt alarm
THIS IS BMS LOCK OUT VOLTAGE
1.5V
1.5V
56V
14V
Recovery voltage
54V
13.5V
Battery over-volt
Bulk Charge = 58V, 62.8, 43.6, 28.6 Float Voltage = 54, 59.2, 40.8, 27
Battery over-volt protection
58.4V
14.6V
Recovery voltage
54V
13.5V
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com
Tomorrow’s Technology Today ™ SOLID STATE BATTERY PARAMETERS
Solid State Lithium 48V 2700Wh
Solid State Lithium 12V 2700Wh
Cut Off Voltage Inverter = 45,11.5
Battery low-volt alarm
46.4V
11.6V
Battery low-volt
Recovery Voltage Inverter = 46.5, 11.8
Recovery voltage
48V
12V
Battery low-volt protection
41.6V
10.4V
Recovery voltage
46V
11.5V
Charge over current alarm
Amps
55A
200A
Recovery
Amps
50A
190A
Charge over current
Nominal Power Max in Watts AT THE BATTERY
Watts
Charge over current protection
Amps
60A
210A
Delay time
Amps
10s
10s
Discharg over current alarm
Amps
55A
200A
Recovery
Amps
50A
190A
Discharg over current
Discharge over current protection
Amps
60A
220A
Delay time
Amps
10s
10s
Peak current
Peak current
Amps
100A
300A
Calculated Power in Watts AT THE BATTERY
Max 30mS (in rush current)
5000W
3700W
Safiery Pty Ltd ABN: 87 624 588 807 45/8 Distribution Court, Arundel QLD 4214 (07) 210 22 55 3 safiery.com sales@safiery.com