Safety
Fusing of Power to Devices
STAR-Switch Custom
STAR-Power
STAR-Light
STAR-Rover
Minimum Power Wire Size Maximum Fuse Size
16mm2
8mm2
6mm2
2.5mm2
150A
50A
50A
10A
The STAR Controller ONLY controls one “leg” of the circuit. Generally positive power but can be configured as negative outputs for STAR-Light and STAR-Rover. For positive output Switching the return negative circuit goes directly to ground or Battery Nega- tive. The return circuits MUST NOT BE CONNECTED TO THE NEGATIVE WIRE OF THE STAR CONTROLERS DIRECTLY OR THE CONTROLLERS WILL NOT FUNCTION. If Switching/Dimming Negative circuits, the positive leg to these circuits MUST BE FUSED INDE- PEDENTLY AND GO TO BATTERY POSITIVE AND NOT TO THE STAR CONTROLLER. STAR controller will protect the power on the negative leg.
ALWAYS connect the Ground Wire in the Plug first before powering up
10
WWW.SAFIERY.COM