Meteor Battery Parameters

This interactive publication describes the best way to get maximum capacity life from an investment in Lithium Batteries in an RV, Caravan, Motorhome or 4WD. Covers the new CANbus technology and the breakthrough in cost reduction from a 48-12V Hybrid.

Meteor Battery Parameters

Copyright Safiery Pty Ltd 2024

T omorrow’s Technology Today ™ METEOR BATTERY PARAMETERS

Lithium 48V 2500Wh

Lithium 48V High Power 2000Wh

Sodium 48V 1700Wh

Lithium 36V 2400Wh

Lithium 24V 2500Wh

Cell Voltages as seen on Victron Display at Battery> Details

Cell over-voltage alarm

V

3.5V

3.5V

3.8V

3.5V

3.5V

Recovery voltage

V

3.4V

3.4V

3.6V

3.4V

3.4V

Cell over- voltage

Cell over-voltage protection

V

3.75V

3.75V

3.95V

3.75V

3.75V

Recovery voltage

V

3.6V

3.6V

3.7V

3.6V

3.6V

Cell low voltage alarm

V

2.7V

2.7V

2.0V

2.7V

2.7V

Recovery voltage

V

2.9V

2.9V

2.35V

2.9V

2.9V

Cell low- voltage

Cell low voltage protection

V

2.5V

2.5V

1.8V

2.5V

2.5V

Recovery voltage

V

2.7V

2.7V

2.2V

2.7V

2.7V

Note this Voltage is between 90-95% SOC

Balance on voltage

54.4

54.4

60

54.4

54.4

Auto Cell Active Balance

Voltage difference of Balance on mV Voltage difference of Balance off mV

mV

3

3

25

3

3

mV

2

2

15

2

2

Battery Voltages V

Low voltage charging prohibition for cell

THIS IS BMS LOCK OUT VOLTAGE

24

24

16

24

24

Battery over-volt alarm

56

56

60.8

42

28

Recovery voltage

54

54

57.6

40.8

27

Battery over-volt

Bulk Charge = 58V, 62.8, 43.6, 28.6

Battery over-volt protection

58.4

58.4

63

43.8

28.8

Safiery Pty Ltd

ABN: 87 624 588 807

45/8 Distribution Court, Arundel QLD 4214

(07) 210 22 55 3 safiery.com

sales@safiery.com

T omorrow’s Technology Today ™ METEOR BATTERY PARAMETERS

Lithium 48V 2500Wh

Lithium 48V High Power 2000Wh

Sodium 48V 1700Wh

Lithium 36V 2400Wh

Lithium 24V 2500Wh

Float Voltage = 54, 59.2, 40.8, 27 Cut Off Voltage Inverter = 45, 38, 36, 24 Recovery Voltage Inverter = 46.5, 40, 37, 25

Recovery voltage

54

54

59.2

40.8

27

Battery low-volt alarm

46.4

46.4

32

34.8

23.2

Battery low-volt

Recovery voltage

48

48

37.6

36

24

Battery low-volt protection

43.2

43.2

30

3.24

21.6

Recovery voltage

48

48

35.2

34.8

24

Charge over current alarm

Amps

55

150

50

55

100

Recovery

Amps

50

145

45

50

95

Charge over current

Nominal Power Max in Watts AT THE BATTERY

Watts

2,500W

7,250W

2,500W

2,000W

2,500W

Charge over current protection

Amps

60

160

60

60

110

Delay time

Amps

10s

10s

10s

10s

10s

Discharg over current alarm

Amps

55

155

50

65

105

Recovery

Amps

50

150

45

60

103

Discharg over current

Discharge over current protection

Amps

60

160

60

70

110

Delay time

Amps

10s

10s

10s

10s

10s

Peak current

Peak current

Amps

150A 30ms

300A 30ms

120A 30ms

150A 30ms

250A 30ms

Calculated Power in Watts AT THE BATTERY

Max 30mS (in rush current)

7,500W

15,000W

7,100W

5,750W

7,000W

Safiery Pty Ltd

ABN: 87 624 588 807

45/8 Distribution Court, Arundel QLD 4214

(07) 210 22 55 3 safiery.com

sales@safiery.com

Meteor Battery LED Indications

LED lamp sequence

1 operational light ,1 alarm light ,4 capacity indicator lights

SOC

ALARM

RUN

Capacity indication

Status

Status

Discharge

Capacity indicator

L4●

L3●

L2●

L1●

L4●

L3●

L2●

L1●

Solid Green Solid Green

0 ~ 25%

Flash Solid Green

OFF

OFF

OFF

OFF

OFF

OFF

Solid Green

25 ~ 50%

Flash

OFF

OFF

OFF

OFF

The remaining capacity

Solid Gree n Solid Gree n

Solid Green

Solid Green

Solid Green

Solid Green

50 ~ 75%

Flash

OFF

OFF

Solid Green

Solid Green

Solid Green

Solid Green

Solid Green

Solid Green

≥75%

Flash

Running indicator light●

Flash

Solid Green

Light Blink explanation

Flash Mode

ON

OFF

Flash 1

0.25s

3.75s

Flash 2

0.5s

0.5s

Flash 3

0.5s

1.5s

State indication

RUN

ALM

SOC

System state

Running state

Note

Shutdow n Standby

Sleep

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Normal

Flash1 Solid Green Solid Green

OFF

OFF

OFF

OFF

OFF

Standby status

Normal

OFF

According to battery indicator

Highest LED flash 2

Alarm

Flash2

According to battery indicator

Highest LED flash 2

overvoltage protection Temperatur e,overcurre nt protection

Charge

Flash1

OFF

OFF

OFF

OFF

OFF

Flash1

Flash1

OFF

OFF

OFF

OFF

According to battery indicator

Normal

Flash3

OFF

According to battery indicator

Alarm

Flash3

Flash3

Temperatur e,overcurre nt, short circuit protection Under- voltage protection

Stop discharging, forced dormancy without action after 48h when the mains is offline

Solid Green

Discharge

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Stopping Discharge

Page 1 Page 2 Page 3 Page 4 Page 5