Meteor Battery Parameters

T omorrow’s Technology Today ™ METEOR BATTERY PARAMETERS

Lithium 48V 2500Wh

Lithium 48V High Power 2000Wh

Sodium 48V 1700Wh

Lithium 36V 2400Wh

Lithium 24V 2500Wh

Cell Voltages as seen on Victron Display at Battery> Details

Cell over-voltage alarm

V

3.5V

3.5V

3.8V

3.5V

3.5V

Recovery voltage

V

3.4V

3.4V

3.6V

3.4V

3.4V

Cell over- voltage

Cell over-voltage protection

V

3.75V

3.75V

3.95V

3.75V

3.75V

Recovery voltage

V

3.6V

3.6V

3.7V

3.6V

3.6V

Cell low voltage alarm

V

2.7V

2.7V

2.0V

2.7V

2.7V

Recovery voltage

V

2.9V

2.9V

2.35V

2.9V

2.9V

Cell low- voltage

Cell low voltage protection

V

2.5V

2.5V

1.8V

2.5V

2.5V

Recovery voltage

V

2.7V

2.7V

2.2V

2.7V

2.7V

Note this Voltage is between 90-95% SOC

Balance on voltage

54.4

54.4

60

54.4

54.4

Auto Cell Active Balance

Voltage difference of Balance on mV Voltage difference of Balance off mV

mV

3

3

25

3

3

mV

2

2

15

2

2

Battery Voltages V

Low voltage charging prohibition for cell

THIS IS BMS LOCK OUT VOLTAGE

24

24

16

24

24

Battery over-volt alarm

56

56

60.8

42

28

Recovery voltage

54

54

57.6

40.8

27

Battery over-volt

Bulk Charge = 58V, 62.8, 43.6, 28.6

Battery over-volt protection

58.4

58.4

63

43.8

28.8

Safiery Pty Ltd

ABN: 87 624 588 807

45/8 Distribution Court, Arundel QLD 4214

(07) 210 22 55 3 safiery.com

sales@safiery.com

Powered by