· ALARM STATE is used to enable or disable the alarm. · ALARM VALUE is a limit value which activates the alarm. · SILENT, if enabled, there will be no audible signal when the alarm activates. The alarm warning will only appear on the screen of the Caravan Panel. · ALARM DELAY is the time delay of the alarm activation. The alarm activates when the measured value is below (for alarm low) or above (for alarm high) the alarm value during the delay period. · ALARM DURATION is the selected duration of the alarm. It is set to 5 minutes by default. · OUTPUT is the digital output that is turned on during an active alarm. 6.9.2.1 Alarm screen When an alarm is triggered, it is shown on the Caravan Panel (see image below). There you can change the alarm state: · Hide hides the alarm from the display, but it is still active in the background. The output is active (if it is set up). · Snooze for 5 or 30 minutes, which means it is hidden for 5 or 30 minutes and then displayed again if still active. The output is active (if it is set up). · Dismiss turns the alarm and output (if it is set up) off for 24h.
If multiple alarms are active at the same time, they are displayed alternately.