Safiery Sensors and GX Tank 140 - User Manual

Configuration The GX Tank 140 requires configuration through the settings menu of the GX Device. This can be accessed either on the display of the GX device or via Remote Console on LAN or VRM. Setup menu

Sensor type (current/voltage) The GX Tank 140 can be used with either voltage or current output sensors. Hence this can be set per channel it is possible to mix different types of sensors. By default the sensor type is set to “voltage”. Setting the wrong type will not damage the GX Tank 140. Fluid type Select from Fuel, Fresh water, Waste water, Live well, Oil and Black water. The selection determines the used icons and colors in the display. In case no specific Tank Name is configured, the Fluid type is shown instead. Volume unit Litre, Cubic meter, Imperial gallon, U.S. gallon. Custom shape It is possible to configure custom shapes for non-linearly shaped tanks. For example for a tank that is wider on the top it can be configured that 50% of sensor reading equals 25% of volume, and 75% equals to 90% of volume. Up to 10 positions can be set. In between, the value will be calculated by interpolation.