Safiery Solid State Lithium Battery
Data Communication
Data Wiring Pinouts CAN cabling Connection is standard NMEA compliant cable Isolated with no power to CAN
420mm
Positive
OUT Reset
120 Ohm Precision resistor inside Solid State Lithium
Any Battery can be a “master”
CAN IN
CAN connection is to Victron Cerbo VE.CAN. Set baud rate at 250baud
Negative
A “blue” Victron CAN plug may be required if this is the only CAN connection
IN (M8 aviation plug)
CAN (M12 aviation plug)
OUT (M8 aviation plug)
RS485B RS485A
RS485B RS485A GND
PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN7 PIN8
PIN1 PIN2 PIN3 PIN4 PIN5
N/A N/A GND
PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN7 PIN8
GND GND R N/A
E T
CAN H CAN L
N/A N/A N/A
RESET+ RESET-
Connection of multiple batteries
Take M8 aviation cable and connect to the “out” of the master battery with the other end connect to the “In” of the second battery Repeat this process till all connected Press the “Reset/On” button at the Master Battery. It will come on and then the string of connected batteries follows If there is a fault in the string or a connection is not screwed in properly, the Master will flash a red light
Remote On/Off/Reset
Connect an M8 cable to the IN of the “Master” battery Pins 7 and 8 are the connections to close with free voltage contacts to remotely turn on DO NOT CONNECT ANYTHING TO PINS 1-5 ON THIS CABLE