Safiery Solid State Lithium Battery Operating Manual V5.1

Safiery Solid State Lithium Battery

Data Communication

Data Wiring Pinouts CAN cabling Connection is standard NMEA compliant cable Isolated with no power to CAN

420mm

Positive

OUT Reset

120 Ohm Precision resistor inside Solid State Lithium

Any Battery can be a “master”

CAN IN

CAN connection is to Victron Cerbo VE.CAN. Set baud rate at 250baud

Negative

A “blue” Victron CAN plug may be required if this is the only CAN connection

IN (M8 aviation plug)

CAN (M12 aviation plug)

OUT (M8 aviation plug)

RS485B RS485A

RS485B RS485A GND

PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN7 PIN8

PIN1 PIN2 PIN3 PIN4 PIN5

N/A N/A GND

PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN7 PIN8

GND GND R N/A

E T

CAN H CAN L

N/A N/A N/A

RESET+ RESET-

Connection of multiple batteries

Take M8 aviation cable and connect to the “out” of the master battery with the other end connect to the “In” of the second battery Repeat this process till all connected Press the “Reset/On” button at the Master Battery. It will come on and then the string of connected batteries follows If there is a fault in the string or a connection is not screwed in properly, the Master will flash a red light

Remote On/Off/Reset

Connect an M8 cable to the IN of the “Master” battery Pins 7 and 8 are the connections to close with free voltage contacts to remotely turn on DO NOT CONNECT ANYTHING TO PINS 1-5 ON THIS CABLE

4

WWW.SAFIERY.COM