Safiery Solid State Lithium Battery Operating Manual V5.1

Safiery Solid State Lithium Battery

Installation Guidelines

Ensure correct polarity when connecting batteries

Batteries can be stacked and connected in parallel

Don not connect in Series, parallel operation only

Connect batteries sequentially from "Out" of the master to "In" of the subsequent units

Press "Reset/On" button on the Master battery to initiate operation

Interconnecting Power Straps

These are made from high grade copper, tin coated flexible fused straps. Their dimensions are 25mm wide and 2mm thick with a cross section of 50mm2

The MAX safe current rating of these straps is 250A

Match this table with maximum load

12V

24V

48V(1C)

48V(3C)

MAXIMUM CURRENT THROUGH THE STRAPS

250A

250A

250A

250A

3,000W

6,250W

12.5kW

12.5kW

5

WWW.SAFIERY.COM

Powered by