STAR-switch Exterior Specification

SAFIERY STAR-SWITCH EXTERNAL Protocol

This document describes the CAN communication protocol for the CAN button operation panel. The key arrangement and corresponding key number (from A1 to B4 respectively) are shown at right: CAN protocol Refer to CAN2.0B Baud rate : 250kBit/s Identifier : 11bit ( Standard frame ) Description: All information in 8 bytes, BYTE0-BYTE 7, multibytes composition data low bytes first, high bytes behind Send a message (key-press message) Identifier: 0x007 (default) Cycle: During power-up, the operation panel is always sent at a 100ms cycle, but immediately when the data changes (key status changes). data:

ID

Byte0 Bit0:A1 Bit1:A2 Bit2:A3 Bit3:A4

Byte1 Bit0:B1 Bit1:B2 Bit2:B3 Bit3:B4

Byte2 0xFF

Byte3 0xFF

Byte4 0xFF

Byte5 0xFF

Byte6 0xFF

Byte7 0xFF

0x007

Description: If the value of the key when the key is pressed, the value of the key is 0. 4 Receive message (indicator light message) Receive the controller data and control the corresponding indicator light according to the received data. Identifier: 0x008 (default) period: 100ms Data: The indicator light receiving the CAN bus data control keys A1 to B4 is turned off

ID

Byte0

Byte1

Byte2

Byte3

Byte4

Byte5

Byte6

Byte7

0x008

Bit0:A1.

Bit0:A3.

Bit0:B1.

Bit0:B3.

1

1

1

1

Bit1:A1.

Bit1:A3.

Bit1:B1.

Bit1:B3.

2

2

2

2

Bit2:A1.

Bit2:A3.

Bit2:B1.

Bit2:B3.

3

3

3

3

Bit3Bac

Bit3: No definitio

Bit3:No definitio

Bit3: No definitio

klight

control enablin

n

n

n

Bit4:A4.

Bit4:B2.

Bit4:B4.

g

1

1

1

Bit4:A2.

Bit5:A4.

Bit5:B2.

Bit5:B4.

1

2

2

2

Bit5:A2.

Bit6:A4.

Bit6:B2.

Bit6:B4.

2

3

3

3

Bit6:A2.

Bit7: No definitio

Bit7: No definitio

Bit7: No definitio

3

Bit7:nc

n

n

n

data Note: 1. If the value of the corresponding bit in the data is equal to 1, the light is on; if the value is equal to 0, the light is out. 2. When the "backlight control enable" is 1, the "backlight control data" is effective, 1 backlight, 0 backlight out

Powered by