CAN key panel function setting The communication node number and port rate of the CAN keyboard are set by the CAN bus data. When setting the CAN panel, the ID number is fixed to 0x7FF and the data format is as follows:
CAN panel function setting the data format The setting parameter (BCDE) exceeds 10 when setting the port rate is invalid; ID number (BCDE) exceeds 0x7FF when setting the standard frame; invalid ID number (BCDE) exceeds 0x1FFFFFFF when setting the extended frame; and invalid BCDE is not 0 or non-0 xFF when setting the power button function. When the setting of node, port rate parameters and power button function meets the requirements, the
parameters will take effect immediately after the setting. Uploading of the system parameter information
In 1S before the panel is powered on (A1-2 indicator light), the CAN key panel sends the system parameter information through 0x7FE at a baud rate of 250 Kbit/s, the specific format is:: CAN Key-press panel system information
ID
Byte0
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
0x7FE
Hardware version number (Low in front, high in back)
Software version number (Low in front, high in back)
0xFF
0xFF
0xFF
0x20 ( or der number )
CAN the Key panel sets the parameter information ID Byte0 Byte1 Byte2 Byte3 Byte4
Byte5
Byte6
Byte7
0x7FE
0x21(or der number)
Porter rate serial number (Low in front, high in back)
Receive d data ID1 type
Data ID1 (low before, high first) )
Receiving data ID type value =0: standard frame format; =1: extended frame format. 0x7FF data is sent by serial number 0-1 for 100ms. 。
Powered by FlippingBook