Simarine and Sensor Wiring Manual

This interactive publication describes the best way to wire up Simarine Products and the supporting sensors.

IRING SYSTEMS

V20180512

SALES@SAFIERY.COM (07) 3040 9560

COPYRIGHT © SAFIERY PTY LTD

WIRING SYSTEMS

PACKAGES ESSENTIAL PACKAGE DIAGNOSTIC PACKAGE PICO PICO ONE MONITOR PICO MONITOR POWER BLOCK / SPLITER

4 5 6

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MOD- ULE CONFIGURATION.

8 9

MODULES SC301 ACTIVE DIGITAL SHUNT SC501 ACTIVE DIGITAL SHUNT SC302T ACTIVE DIGITAL SHUNT SCQ25 QUADRO DIGITAL SHUNT SCQ25T COMBO ST107 DIGITAL TANK MODULE

12 14 16 18 20 22

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

3

PICO

4 PICO one MONITOR Description PICO one is SIMARINE’s new entry level battery monitor with the Real- Time Battery Health™ Algorithm for precise battery health measurements. Coupled with a compatible with a SC302T combo shunt presents a perfect battery monitoring system for boats and caravans with one service battery bank up to 300A on 12V, 24V, 48V, 60V and 72V, one or two engine/backup battery banks and up to 2 tanks. PICOone’s display unit is made of a sleek anodized aluminum casing and a thick Gorilla® Glass with Anti-Reflective coating protecting the optically bonded high- contrast 3.5 inch IPS LCD display. It’s water and dust proof and can be mounted both indoors and outdoors. The screen brightness is automatically adjusted with a light sensor. The device is operated by four water tolerant CapSense® touch buttons. The barograph gives precise air-pressure readings, trends, and history. Free SIMARINE Android and iOS Apps are available to connect your PICOone to your smartphone via Wi-Fi. The Apps allow you to monitor all battery and tank data, upload history, edit and restore settings and even upgrade the firmware for adding new features.

Technical Specification

Operation

Voltage range 6 – 35 V Temperature range -10 – +70 °C Barometer operating range 950-1080 hPa Wifi radio frequency bands 2.4GHz Logger capacity up to 3 months

Power Consumption at 12V

Operating, wifi on, 100% illumination 90 mA Operating, wifi on, 70% illumination 35 mA Stand by, wifi off, 0% illumination 18 mA Power off, logger still active 5 mA

Resolution

Current

± 0.01A

State of charge (0-100%)

± 0.1%

Voltage ± 0.01V

Temperature ± 0.1°C

Amp hour

± 0.1Ah

Amp hour

± 0.1Ah

Number of connections

Max number modules connected 1(SC302T only)

General Specification

Monitoring capabilities (PICO one Display unit only)

Monitoring voltage 12V, 24V Battery voltage 1

LCD TFT 3,5” High resolution IPS, Gorilla Glass, anti-reflective coating

Display

Monitoring capabilities (on SC302T combo shunt)

Human interface 4 Touch buttons, water resistant

Monitoring voltage 12 V, 24 V, 48 V, 60 V, 72 V(SC302T)

Enclosure CNC-milled anodized aluminum, water- and dustproof Mounting type Panel-Mount, Standalone

Max current 300A continuous 400A peak (<1min) Batteries 1 (Current & Voltage ) 2 (Voltage)

Panel-Mount: HxWxD 108.5 x 94 x 10 mm Standalone: HxWxD 98 x 83 x 10 mm

Dimensions

Tanks Level or Temperature sensors

2 Smartphone application 1

Color Black, Silver Mounting type Panel-Mount, Standalone

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

5 Description PICO is SIMARINE’s advanced battery monitor and the Real-Time Battery Health™ Algorithm for precise battery health measurements. It sets new standards for marine battery monitors in fields of design, functionality, connectivity and ease of use. Compatible with all SIMARINE shunts and modules. Its expandable architecture allows adding up to 20 SIMARINE shunts and modules to monitor all kinds of boats, yachts and caravans – from a small one to a superyacht system with up to 6 battery banks, 14 tanks and 20 independent consumer and generators. PICO’s display unit is made of a sleek anodized aluminum casing and a thick Gorilla® Glass with Anti-Reflective coating protecting the optically bonded high-contrast 3.5 inch IPS LCD display. It’s water and dust proof and can be mounted both indoors and outdoors. The screen brightness is automatically adjusted with a light sensor. The device is operated by four water tolerant CapSense® touch buttons. The (optional) barograph gives precise air-pressure readings, trends, and history. Free SIMARINE Android and iOS Apps are available to connect your PICO to your smartphone via Wi-Fi. The Apps allow you to monitor all battery and tank data, upload history, edit and restore settings and even upgrade the firmware with new features. PICO PLUS MONITOR

Technical Specification

Operation

Voltage range 6 – 35 V Temperature range -10 – +70 °C Barometer operating range 950-1080 hPa Wifi radio frequency bands 2.4GHz Logger capacity up to 3 months

Power Consumption at 12V

Operating, wifi on, 100% illumination 90 mA Operating, wifi on, 70% illumination 35 mA Stand by, wifi off, 0% illumination 18 mA Power off, logger still active 5 mA

Resolution

Current

± 0.01A

State of charge (0-100%)

± 0.1%

Voltage ± 0.01V

Temperature ± 0.1°C

Amp hour

± 0.1Ah

Amp hour

± 0.1Ah

Number of connections

Max number modules connected 20 (all SIMARINE shunts and modules)

General Specification

Monitoring capabilities (PICO Display unit only)

Monitoring voltage 12V, 24V Battery voltage 1 Monitoring capabilities (with SIMARINE shunts and modules)

LCD TFT 3,5” High resolution IPS, Gorilla Glass, anti-reflective coating

Display

Human interface 4 Touch buttons, water resistant

Monitoring voltage 12 V, 24 V(SC300,SC500, ST107,SCQ25T) 12 V, 24 V, 48 V, 60 V, 72 V(SC302T) Batteries 6 (Current & Voltage ), 6 (Voltage)

Enclosure CNC-milled anodized aluminum, water- and dustproof Mounting type Panel-Mount, Standalone

20

Independent consumer or generators current channels

Panel-Mount: HxWxD 108.5 x 94 x 10 mm Standalone: HxWxD 98 x 83 x 10 mm

Dimensions

Tanks Level sensors

14

Color Black, Silver Mounting type Panel-Mount, Standalone

Temperature sensors

10

Inclinometer sensors 2 Smartphone application 1

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

6 Description POWER BLOCK device is the power hub for the Pico and Modules throughout the system. This means there is only one point of applying 12V or 24V power and it is distributed through the system automatically. This requires only one fuse point. The power block can be located a metre away from the pico display allowing it to be installed out of the way and down at a lower level. The block has 4 points of access for the twisted pair cables to modules. Cable lengths: Greater than 5m, use 2 x 2 x 0.25 mm 2 twisted pair.

POWER BLOCK / SPLITTER

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

10

MODULES

12

SC301 ACTIVE DIGITAL SHUNT

Description SC301 active shunt precisely monitors battery voltage on 12V and 24V systems, battery temperature and continuous currents up to 300A (400A peak). It’s suitable for maximal power of 3600W at 12V or 7200W at 24V. Additionally, it can also be used for monitoring current draw of heavy consumers like inverters, bow and stern thrusters and anchor winches and current generated on generators like shore power chargers, solar panels, hydro- and wind generators. SC301’s innovative protected architecture allows wiring in either negative (low) or positive (high) side.

Technical Specification

Operation

Voltage range 6 – 35 V Temperature range -20 – +70 °C

Power Consumption at 12V

Operating 0,8 mA

Current Measuring

Range 0,01 – 320 A

Accuracy ± 0,6 % Resolution 0,01 A Sampling rate 100 ms

Maximal Current

Continuous

300 A 400 A

Peak current ( <1min )

Voltage Measuring

Range 0 – 35 V Accuracy ± 0,2 % Resolution 1 mV

Temperature Sensor – NTC 5K

Range -15 – +80 °C Accuracy ( -10 – +60 °C ): 3 %

Installation and Dimensions

Dimensions

118x40x52 mm

Connection M 10 bolts

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

13

12V Power

To next Simarine Device

Refrigerator

Light

Pump

Outside

12V Outlets

Inverter

SC301 ACTIVE DIGITAL SHUNT

Main Switch

TEMPERATURE SENSOR INPUT

FIRST BATTERY (System) (Voltage & Current)

OR

SECOND BATTERY (Voltage Only)

ONLY Voltage Level Sensor

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION. V2.1

14

SC501 ACTIVE DIGITAL SHUNT

Description

Technical Specification

SC501 active shunt precisely monitors battery voltage on 12V and 24V systems, battery temperature and continuous currents up to 500A (600A peak). It’s suitable for maximal power of 7200W at 12V or 14400W at 24V. Additionally, it can also be used for monitoring current draw of heavy consumers like inverters, bow and stern thrusters and anchor winches and current generated on generators like shore power chargers, solar panels, hydro- and wind generators. SC500’s innovative protected architecture allows wiring in either negative (low) or positive (high) side. Up to 12 modules can be connected simultaneously for battery (6) and current (6) measurements (only on PICO Battery Monitor).

Operation

Voltage range 6 – 35 V Temperature range -20 – +70 °C

Power Consumption at 12V

Operating 0,8 mA

Current Measuring

Range 0,02 – 600 A

Accuracy ± 0,6 % Resolution 0,02 A Sampling rate 100 ms

Maximal Current

Continuous

500 A 800 A

Peak current ( <1min )

Voltage Measuring

Range 0 – 35 V Accuracy ± 0,2 % Resolution 1 mV

Temperature Sensor – NTC 5K

Range -15 – +80 °C Accuracy ( -10 – +60 °C ): 3 %

Installation and Dimensions

Dimensions

118x40x52 mm

Connection M 10 bolts

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

15

12V Power

To next Simarine Device

Refrigerator

Light

Pump

Outside

5

12V Outlets

Inverter

SC501 ACTIVE DIGITAL SHUNT

Main Switch

TEMPERATURE SENSOR INPUT

FIRST BATTERY (System) (Voltage & Current)

OR

SECOND BATTERY (Voltage Only)

ONLY Voltage Level Sensor

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION. V2.1

16

SC302T ACTIVE DIGITAL SHUNT

Description SC302T is an innovative combination of shunt and tank level module. SC302T active combo shunt precisely monitors battery voltage on 12V, 24V, 48V, 60V and 72V systems, battery temperature and continuous currents up to 300A (400A peak). It’s suitable for maximal power of 3600W at 12V or 7200W at 24V. It is equipped with one additional battery voltage input (2 in total). The integrated tank level module has 2 resistance-type inputs for monitoring tank level and temperature sensors Additionally, the SC302T module can also be used for monitoring current draw of heavy consumers like inverters, bow and stern thrusters and anchor winches and current generated on generators like shore power chargers, solar panels, hydro- and wind generators. SC302T’s innovative protected architecture allows wiring in either negative (up to 72V) or positive (up to 24V) side

Technical Specification

Operation

Voltage range 6 – 35 V Temperature range -20 – +70 °C

Power Consumption at 12V

Operating 1.2 mA

Current Measuring

Range 0,01 – 320 A

Accuracy ± 0,6 % Resolution 0,01 A Sampling rate 100 ms

Maximal Current

Continuous

300 A 400 A

Peak current ( <1min )

Voltage Measuring

Range 0 – 70 V Accuracy ± 0,2 % Resolution 1 mV

Temperature Sensor – NTC 5K

Range -15 – +80 °C Accuracy ( -10 – +60 °C ): 3 %

Installation and Dimensions

Dimensions

120x120x60 mm

Connection M 10 bolts

Resistance Inputs

Range 0 ohm – 65 kohm Accuracy ± 3,0 %

Number of connections

Tank level/temperature sensors

2

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

17

12V Power To next Simarine Device

Refrigerator

Light

Pump

Outside

12V Outlets

Small Inverter

SC302T ACTIVE DIGITAL SHUNT

Main Switch

TEMPERATURE SENSOR INPUT

ONLY Voltage Level Sensor

FIRST BATTERY (System) (Voltage & Current)

TEMPERATURE SENSOR INPUT

OR

SECOND BATTERY (Voltage Only)

ONLY Voltage Level Sensor

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION.

V2.1

18

SCQ25 QUADRO DIGITAL SHUNT

Description

Technical Specification

SCQ25 is an innovative shunt module with four inputs for monitoring individual consumer and generator continuous currents up to 25A (35A peak) per input on 12V and 24V systems. That is very convenient for monitoring smaller consumers like refrigerator or generators like solar, wind, hydro or shore power. The current channels can be combined for higher amperage, meaning the continuous currents on the combined channels up to 50A (70A peak) on 12V and 24V volts. SCQ25’s innovative protected architecture allows wiring in either negative (low) or positive (high) side. Up to five modules can be connected simultaneously to monitor up to 20 current channels (only on PICO Battery Monitor)

Operation

Voltage range 6 – 35 V Temperature range -20 – +70 °C

Power Consumption at 12V

Operating 3.5 mA

Current Measuring

Current measuring channels

4

Per channel

0,01 – 50 A

Accuracy ± 0,6 % Resolution 0,01 A Sampling rate 100 ms

Maximal Current

Continuous

25 A 35 A

Peak current ( <1min )

Peak current ( <5min )

50 A Voltage frop at 25A 35mV

Maximal voltage on connections

35V

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

19

12V Power

Refrigerator

Light

Solar 40A

Pump

12V Outlets

Inverter

SCQ25 QUADRO DIGITAL SHUNT

Main Switch

Note 40A Solar Circuit can be split into 2 channels of 25A max each for one combined reading.

FIRST BATTERY (System) (Voltage & Current)

TEMPERATURE SENSOR INPUT

OR

SECOND BATTERY (Voltage Only)

ONLY Voltage Level Sensor

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION. V2.1

20

SCQ25T COMBO QUADRO DIGITAL SHUNT + TANK MODULE

Description

Technical Specification

SCQ25T is a highly verstaile and innovative combination of shunt, tank interface and voltage module. Its higly innovative shunt module with four inputs for monitoring individual consumer and generator continuous currents up to 25A (35A peak) per input on 12V and 24V systems. Additionally, equipped with four resistance inputs for resistance-type tank level or temperature sensors and three voltage inputs for voltage-type tanks sensors and battery voltages allows wide connection possibilities. That is very convenient for monitoring smaller consumers like refrigerator or generators like solar, wind, hydro or shore power. The current channels can be combined for higher amperage, meaning the continuous currents on the combined channels up to 50A (70A peak) on 12V and 24V volts. SCQ25T’s innovative protected architecture allows wiring in either negative (low) or positive (high) side.

Operation

Voltage range 6 – 35 V Temperature range -20 – +70 °C

Power Consumption at 12V

Operating 3.5 mA

Current Measuring

Current measuring channels

4

Per channel

0,01 – 50 A

Accuracy ± 0,6 % Resolution 0,01 A Sampling rate 100 ms

Maximal Current

Continuous

25 A 35 A

Peak current ( <1min )

Peak current ( <5min )

50 A Voltage frop at 25A 35mV

Maximal voltage on connections

35V

Voltage Inputs

Range 0 – 35 V Accuracy ± 0,2 % Resolution 1 mV Sampling rate 100ms

Resistance Inputs

Range 0 ohm – 65 kohm Accuracy ± 3,0 %

Number of connections

Tank level sensors Temperature sensors

7 4

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

21

Note 40A Solar Circuit can be split into 2 channels of 25A max each for one combined reading.

7

5

6

2

1

3

4

8

V

V

V

0 - 35V DC

0 - 65kOHM

S CQ 25T

SiCOM

COM NC

NO

12V Power

Refrigerator

Light

Solar 40A

Pump

12V Outlets

Inverter

SCQ25T COMBO QUADRO DIGITAL SHUNT +TANK MODULE

UP TO 4 UNITS

UP TO 3 UNITS

RESISTANCE INPUTS

VOLTAGE INPUTS

Main Switch

Resistance Level Sensor

Voltage Level Sensor

FIRST BATTERY (System) (Voltage & Current)

TEMPERATURE SENSOR INPUT

Voltage Level Sensor

Resistance Level Sensor

OR

OR

NTC 10k

Battery Bank

Temperature

OR

OR

SECOND BATTERY (Voltage Only)

ONLY Voltage Level Sensor

Inclinometer Pitch > 1 Input Tilt > 1 Input

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION. V2.1

22

ST107 DIGITAL TANK MODULE

Description

Technical Specification

ST107 Digital tank module is a highly versatile module. Its main purpose is to measure any liquid level. But it can be used to measure voltage, current or temperature. ST107 Digital tank module can measure liquid level such as water, waste water, fuel or any other liquid. It comes with 4 integrated resistance sensing inputs operating from 0 ohm - 65 kohm and 3 integrated voltage sensing inputs, operating from 0V - 35 V DC. You can connect any tank or temperature sensor operating in this range. ST107 also features a configurable alarm contact, which fires on specific alarms. It can handle max. current 1A on max. 30 V DC. The alarm is configurable via PICO’s menu.

Operation

Voltage range 6 – 35 V Temperature range -20 – +70 °C (-4 - 158 °F)

Power Consumption at 12V

Operating 2.5 mA

Voltage Inputs

Voltage measuring channels

3 Range 0 – 35 V Accuracy ± 0,2 % Resolution 1 mV

Sampling rate 10ms

Resistance Inputs

Range 10 ohm – 65 kohm Accuracy ± 0.1 %

Sampling rate 10ms Dimensions

112x72x31mm

Number of connections

Tank level sensors*

7

Temperature sensors**

4

SICOM port

2

Alarm contact

1

* Maximal number of connected tank sensors to one ST107 digital tank module. This includes 4 resis- tance and 3 voltage sensing inputs, which excludes connecting any temperature sensor. ** Maximal number of connected temperature sensors to one ST107 digital tank module, which excludes connecting any tank sensor

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTSIMAGES AND TEXT IN THIS EBOOK ARE SUJECT TO COPYRIGHT

23

Accessory Main Switch

12V Power To another SiCOM port

SiCOM

S T 10 7

0 - 6 5kOHM

0 - 35V DC

V

V

V

NC NO

COM

COM

11 R 4

R 3

U2

R 2

U1 GND

U3

R 1

12

7

9

10

8

2 1

6

5

4

3

ST107 DIGITAL TANK MODULE

UP TO 3 UNITS

UP TO 3 UNITS

VOLTAGE INPUTS

RESISTANCE INPUTS

0-65 koHM

ONLY Voltage Level Sensor

Resistance Level Sensor

OR

OR

TEMPERATURE SENSOR

BATTERY BANK (Voltage ONLY)

INPUT NTC 10 koHM -15 - 90 °C

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION. V2.1

Note 40A Solar Circuit can be split into 2 channels of 25A max each for one combined reading.

7

5

6

2

1

3

4

8

V

V

V

0 - 35V DC

0 - 65kOHM

S CQ 25T

12V Power

SiCOM

COM NC

NO

SCQ25T COMBO QUADRO DIGITAL SHUNT +TANK MODULE

UP TO 4 UNITS

UP TO 3 UNITS

RESISTANCE INPUTS

VOLTAGE INPUTS

Main Switch

Resistance Level Sensor

Voltage Level Sensor

FIRST BATTERY (System) (Voltage & Current)

TEMPERATURE SENSOR INPUT

Voltage Level Sensor

Resistance Level Sensor

OR

OR

NTC 10k

SC301 ACTIVE DIGITAL SHUNT

Battery Bank

Temperature

OR

OR

SECOND BATTERY (Voltage Only)

ONLY Voltage Level Sensor

Inclinometer Pitch > 1 Input Tilt > 1 Input

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION. V2.1

SENSORS CATALOG

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD

THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION.

TEMPERATURE SENSORS STB01 BATTERY TEMPERATURE SENSOR

PRESSURE SENSOR SPH01 PRESSURE SENSOR SPR01 PRESSURE SENSOR-REFRIGERANT

21 22

4 5 6

STG01 WATERPROOF INTERNAL TEMPERATURE SENSOR STS01 WATERPROOF EXTERNAL TEMPERATURE SENSOR TANK LEVEL SENSORS STLU01 ULTRASONIC TANK LEVEL SENSOR IP68 STLPS01 SUBMERSIBLE TANK LEVEL SENSOR (Inside) IP68 STLPO01 TANK LEVEL SENSOR (Outside Fitting Bottom) IP67 STLC01 COMPACT TANK LEVEL SENSOR IP65 STLWXXX WEMA STYLE TANK LEVEL SENSOR N/A SOLAR PERFORMANCE SENSOR SSP01 SOLAR PERFORMANCE SENSOR

CABIN SENSOR SCP01 CABIN PRESSURE SENSOR SCD01 CABIN DUST SENSOR SCC01 CABIN CO2 SENSOR SCS01 CABIN SO2 SENSOR

24 25 26 27

10 11 12 13

LOAD SENSOR GVW01AXLE LOAD SENSOR

31

15

INCLINOMETER SENSOR SIN01 INCLINOMETER SENSOR AC CURRENT SENSOR SAC01 AC CURRENT SENSOR

17

20

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

3

TEMPERATURE SENSOR

4 STB01 BATTERY TEMPERATURE SENSOR Description Technical Specification

STB01 Temperature Sensor is Epoxy resin wrapped NTC sensor connected with insulated wire. It is waterproof with moisture protection, good insulation, high reliability, and sensitive response. The flat fixable probe is designed for monitoring the temperature of the battery. It works with Simarine Monitoring System and Smartphone App. Alerts can be sent if the temperature exceeds or drops below a preset level. The Temperature Sensor is especially critical for Lithium batteries in extreme climates.

Performance

Recommended application Battery Protection level Waterproof

Probe type Nickel plated copper flat fixable probe Probe size 9 x 10 mm, Inner diameter 4mm Length of wire 2 m Output 2 wires

Electrical Characteristic

Supply voltage 12V DC Measurement range - 20 – + 60 °C

Type NTC 10k ±1% 3950

B-constant

3380K ±1%

Typical Dissipation Constant 5mW/ °C Probe insulation >100MOhm Peak voltage sustain time 2 seconds, AC1800V 1mA 2 seconds Stress sustain 9.8N (1kgF) for 1 minute no deformation

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

5 STG01 WATERPROOF INTERNAL TEMPERATURE Description Technical Specification

STG01 Temperature Sensor is Epoxy resin wrapped NTC sensor connects with insulated wire. It is waterproof with stainless steel probe, moisture protection, good insulation, high reliability, and sensitive response. This temperature sensor is designed for monitoring the temperature of general devices, especially a fridge. To use with fridge, drill a 5mm hole from rear and insert the stainless steel probe with adhesive. It works with Simarine Monitoring System and Smartphone App. Alerts can be sent if the temperature exceeds or drops below a preset level. The Temperature Sensor is especially critical for boaters and RV relying on heating and cooling systems in extreme climates.

Performance

Recommended application Fridge Protection level

Waterproof Probe type Stainless steel probe Probe size 4.2 x 33 mm Length of wire 5 m Output 2 wires

Electrical Characteristic

Supply voltage 12V DC Measurement range - 20 – + 80 °C

Type NTC 10k ±1% 3950

B-constant

3380K ±1%

Typical Dissipation Constant 5mW/ °C Probe insulation >100MOhm Peak voltage sustain time 2 seconds, AC1800V 1mA 2 seconds Stress sustain 9.8N (1kgF) for 1 minute no deformation

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

6 STS01 WATERPROOF EXTERNAL TEMPERATURE Description Technical Specification

STS01 Temperature Sensor is Epoxy resin wrapped NTC sensor connects with insulated wire. It is waterproof with moisture protection, good insulation, high reliability, and sensitive response. The stainless steel braided sheath is durable and the sensor can work in the high temperature environment. This high quality sensor is designed for monitoring the temperature of the shock absorber. It works with Simarine Monitoring System and Smartphone App. Alerts can be sent if the temperature exceeds or drops below a preset level. The Temperature Sensor is especially critical for boaters and RV relying on heating and cooling systems in extreme climates.

Performance

Recommended application Shock Absorber Protection level

Waterproof & Heat resistant

Probe type Stainless steel probe Probe size 4 x 90 mm Length of wire 2 m stainless steel braided cable Output 2 wires

Electrical Characteristic

Supply voltage 12V DC Measurement range 0 – + 250 °C

Type NTC 50k ±1% 3950

B-constant

3380K -/+ 1%

Typical Dissipation Constant 5mW/ °C Probe insulation >100MOhm Peak voltage sustain time 2 seconds, AC1800V 1mA 2 seconds Stress sustain 9.8N (1kgF) for 1 minute no deformation

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

9

TANK LEVEL SENSORS

10 STLU01 ULTRASONIC TANK LEVEL SENSOR Description Technical Specification

STLU01 Ultrasonic Tank Level Sensor with analog voltage output adopts the ultrasonic ranging principle THROUGH the measuring Liquid. It uses a special probe attached to the under-face (bottom) of the measured container to measure the level of the liquid level. It is suited to metal tanks. Special ultrasonic sensor using advanced high-speed signal processing technology is good for tanks up to 1.0m high. The assessed liquid level in the tank is calculated accurately by using the special algorithm. The measurement output is 0-5VDC signal. The design of this sensor suits RV manufacturers, The sensor has an LED on the underside. This is solid when 12V power is available. The sensor is placed by hand to the position where it will be adhered. The LED will flash to confirm the ultrasonic response is good and not fouled by baffles or pumps etc. When glued into position, excess glue is trapped in the glue recovery recess in the base of the unit. The material is anodized aluminium alloy of fine quality. The liquid level sensor has no special requirement on the material in the tank. Installation 1. The sensor needs to be placed in the centre at the bottom of the container. To make make sure there is no obstacle in the detection range there is an LED that “flashes” during installation. Bafles and other obstacles can therefore be avoided. Read on.. 2. Clean the detecting surface of the tank. If the metal tank has a paint coating, the surface of the detecting point has to be

Performance Recommended application Water Tank IP68

Measurement mode Non-contact

Length of wire 450mm

Size (LxWxH)

50x50x17 mm

Work temperature - 15 – +60 °C

Storage temperature - 25 – +80 °C

Electrical Parameters

Working voltage 10-36V DC

Average current

<25mA

Measuring height of liquid level Response time (without water)

Blind zone ≤50mm

50-1,000mm

Response time (with water)

2s

2s

Output mode Analog voltage

Resolution 1mm

Center frequency

2mHz

ESD ±4/±8KV

Accuracy (normal temperature)

±(10 + current height of liquid level*1%)

LED indicator light instructions Long bright

Power on, but did not detect the liquid Slow flash Liquid is detected and the LED flashes at one frequency per second

Electronic Wire Connections

Red VCC

Black GND

sanded until the metal is clean and polished. 3. If testing before final installation, press the sensor on the detecting point with ‘ coupling material’ (KY Jelly is best) for testing. When the LED is flashing, it confirms that it is good position for final installation. 4. Install the sensor permanently on the detecting point using a ‘ two part epoxy adhesive ’ 5. If the tank is poly-ethylene (roto-moulded tanks), it is advised to gently heat the area that you will be gluing to with a cigarette lighter to drive out any oils prior to gluing.

Yellow Signal Output +

White Reserved for later use

The Relational Graph Between Distance and approx voltage out.

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

11 STLCO01 COMPACT TANK LEVEL SENSOR (Fitted External Bottom) Description STLPO01 Pressure Sensor uses a high quality piezo-resistive pressure sensor (or flush ceramic sensor). It has an isolated stainless steel diaphragm as signal sensing element. Quality assembly procedures include: • Automatic testing, laser trimming compensated zero Technical Specification Parameter Pressure range 0-500mm Water Signal output 0-5V Power supply Overload 150%.F.S 1.5-2%.F.S

Measuring medium Fresh Water

12V DC

Burst pressure 200%F.S

Accuracy (Linearity hysteresis repeatability)

Stability 0.2%F.S ± 0.05%

• Special sensitivity in wider temperature range • Amplifier circuit is in stainless steel housing, • Transforming sensor signal into standard output signal.

Working Temperature -30°C~80°C

Storage temperature -40°C~85°C

Zero temperature drift

≤ 0.02%.F.S/°C/year

Net Weight

0.1kg

Piezo-resistive Flush Ceramic

Housing material

316 Stainless Steel

Diaphragm material

Insulate resistance >100MΩ @50V

Response time ≤10ms

Electronic Wire 3 Wires

Electronic connection Directly sealed cable IP67

Pressure connect port

G1/4” NPT male

Cable specs Water Proof

2m PE cable

Certificate approving CE Certificate

IP65

EMC Standard Electromagnetic radiation: EN50081-1/-2 Electromagnetic susceptibility: EN50082-2

Dimension and Drawing (mm)

Electronic Wire Connections

Red Power Supply +

Blue or Green Power Supply - Blue or Green Signal Output -

Blue or Green Ground Wire

Yellow Signal Output +

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

12 STLPS01 SUBMERSIBLE TANK LEVEL SENSOR Description STLPS01 Pressure Tank Level Sensor is a full sealed submersible level transducer/ transmitter. It is a highly stable and reliable piezo-resistive pressure sensor with an accurate circuit board in a stainless steel housing. It is an integrated construction with a standard control signal. The special cable is integrated with the housing and can be immersed into water for a long time. This sensor has compact size, light weight and good stability. It is rated as food grade. Parameter Measuring range 0-500mm, H2O Measuring medium Drinking Water Signal output 0-5V Power supply 12V DC Overload 150%.F.S Burst Pressure 300%F.S Accuracy (Linearity hysteresis repeatability) ≤ ± 1%.F.S Long Stability 0.2%F.S ± 0.05% Working Temperature -30°C~80°C Storage temperature -40°C~90°C Zero temperature drift ≤ 0.03%.F.S/°C/year Net Weight 0.1kg Housing material 304 Stainless Steel Diaphragm material Technical Specification

Piezo-resistive Flush Ceramic

Process material

304 Stainless Steel

Process material

304 Stainless Steel

Insulate resistance >100MΩ @50V

Response time ≤10ms

Electronic Wire 3 Wires

Electronic connection Directly sealed cable IP67

Pressure connect port

G1/4”

Cable specs Water Proof

1m PE cable

Certificate approving CE Certificate

IP68

EMC Standard Electromagnetic radiation: EN50081-1/-2 Electromagnetic susceptibility: EN50082-2

Dimension and Drawing (mm)

Electronic Wire Connections

Red Power Supply +

Black Power Supply -

Blue & Green Signal Output +

White/Yellow Signal Output -

Yellow Ground Wire

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

13 STLPO01 TANK LEVEL SENSOR (Fitted External Bottom) Description STLPO01 Pressure Sensor uses a high quality piezo-resistive pressure sensor (or flush ceramic sensor). It has an isolated stainless steel diaphragm as signal sensing element. Quality assembly procedures include: • Automatic testing, laser trimming compensated zero Technical Specification Parameter Pressure range 0-500mm Water Measuring medium Fresh Water Signal output 0-5V Power supply 12V DC Overload 150%.F.S Burst pressure 200%F.S Stability 0.2%F.S ± 0.05% 1.5-2%.F.S

Accuracy (Linearity hysteresis repeatability)

• Special sensitivity in wider temperature range • Amplifier circuit is in stainless steel housing, • Transforming sensor signal into standard output signal.

Working Temperature -30°C~80°C

Storage temperature -40°C~85°C

Zero temperature drift

≤ 0.02%.F.S/°C/year

Net Weight

0.1kg

Piezo-resistive Flush Ceramic

Housing material

316 Stainless Steel

Diaphragm material

Insulate resistance >100MΩ @50V

Response time ≤10ms

Electronic Wire 3 Wires

Electronic connection Directly sealed cable IP67

Pressure connect port

G1/4” NPT male

Cable specs Water Proof

2m PE cable

Certificate approving CE Certificate

IP67

EMC Standard Electromagnetic radiation: EN50081-1/-2 Electromagnetic susceptibility: EN50082-2

Dimension and Drawing (mm)

Electronic Wire Connections

Red Power Supply +

Blue or Green Power Supply - Blue or Green Signal Output -

Blue or Green Ground Wire

Yellow Signal Output +

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

14 STLWXXX WEMA STYLE TANK LEVEL SENSOR Description Technical Specification

STLW200, STLW400 & STLW450 WEMA Style Sensors for both fuel and water provides highly accurate level measurement for a wide variety of applications, including those in severe environments. Measurement is done using “hall effect” with reed switches positioned inside the level tube. A float with built-in magnets then triggers the reed relays generating a potential - free resistance with an ohm value that increases or decreases. The float is the only moving part of the sensors, thereby minimising potential mechanical failures. All sensors are fully insulated to protect against voltage inside the tank. The level sensors are made of stainless steel and can be mounted in almost any tank shape either by standard 5-hole configuration.

Parameter

200mm, 400mm, 450mm 240-33 Ω

Sensor Size

Measuring medium Fuel,Oil, Water

Signal output

Resolution 21mm

Working Temperature -40°C~85°C

Response time 0.1s

316 Stainless Steel OR 304 Stainlless Steel

Housing material

Mounting method Standard SAE 5 hold pattern

Protection Rank

IP67

Cable specs

50cm PVC cable

Dimension and Drawing (mm)

Instructions

To test correct operation, unscrew fuel sender, connect two wires to multimeter, set to resistance and move float up and down by hand. With float at the bottom it should read 0 ohm and at the top 180 ohm.

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

15 SLPG01 ULTRASONIC LPG TANK LEVEL SENSOR Description Technical Specification

SLPG01 Ultrasonic LPG Tank Level Sensor with analog voltage output adopts the acoustic reflection principle of the LPG tank level through a special conductive elastomer couplant to the metal LPG tank. It uses a circular rare earth magnet to attach to the under-face (bottom) of the LPG tank. Fitted between the Acoustic sensor and the tank is the special conductive elastomer couplant material. Inside the ultrasonic housing is a calibrated thermistor. The system sensor uses special ultrasonic processing technology. The echo signals are detected by the probe after being reflected back from the liquid surface. The echo signal is processed by the proprietary algorithm and the time is calculated. The system calculates the level of LPG according to the formula. There is no special requirement on the tank size. Installation 1. The sensor needs to be placed in the centre at the bottom of the LPG Tank. Please make sure there is no loose paint or debris at this point. 2. Clean the bottom surface of the LPG tank. If the metal tank has a thick or over- painted coating, the surface of the detecting point has to be clean and polished. 3. Place the couplant pad between the sensor and bottom of the tank. 4. Fit the alloy housing and magnetic ring to bottom of LPG tank. This is a strong connection which compresses the couplant material. 5. Check that the LED is flashing, as this confirms that it is good connection.

Performance Recommended application Water Tank IP68

Measurement mode Non-contact

Length of wire 2000mm

Size (LxWxH)

50x50x20 mm

Work temperature - 15 – +60 °C

Storage temperature - 25 +80 °C

Electrical Parameters

Working voltage 10-36V DC

Average current

<25mA

Blind zone ≤50mm

Measuring height of LPG level Accuracy (normal temperature)

50-1,000mm

Response time (with water)

2s

± 4%

Output mode Analog voltage

Resolution 1mm

Center frequency

2mHz

ESD ±4/±8KV

LED indicator light instructions

Slow flash LED flashes every second for valid couplant engagement

Electronic Wire Connections

Red 12V power to sensor Yellow Signal Output

Black GND signal output/temp White Temperature

COUPLANT

CIRCULAR MAGNETIC MATERIAL

TEMPERATURE SENSOR

ULTRA SONIC DEVICE (AE)

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

18

AC CURRENT SENSOR

19 SAC01 AC CURRENT SENSOR Description SAC01 AC Current Sensor provides a calibrated DC output proportional to the AC current input. It is set on a range of 0-30A input AC current. With this sensor, you will see the amount of shore or site power coming in. When set with low alarm, it will signal if you lose AC power input for whatever reason. Designed for multi-point current sensing, it uses classic current isolation and measurement systems. Performance Size (LxWxH) DIN rail

Technical Specification

95×37×88.5 mm 35mm Panel mount

Weight

120g

Aperture Size 20mm

Electrical Parameters Standard application IEC688:1992

Input range 0 - 30A

-10 ~ 50°C,20% -90%,non condensing Storage environment

-40 ~ 70°C,20% -95%,non condensing

Working environment

This device provide excellent ability for anti interference with accuracy of 0.5%. Average RMS is used when sensing current waveforms that have a fixed frequency.

Basic accuracy ≤0.5%.F.S

Calibration RMS calibrated Average sensing Output load 0-5V dc – 2k Ohm

Thermal drift

≤100PPM/°C (0~50°C)

Power consumption ≤30mA+output current

Power source 12V

Isolation voltage ≥100MΩ(DC500V)

Response time

≤300mS

Dimension and Drawing (mm)

Wiring Diagram

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

20 SAC01 AC CURRENT SENSOR Instruction of Installation and Use

Caution: 1. Pay attention to the auxiliary power information, especially the auxiliary power grade, and polarity, other wise will damage the product. 2. Pay attention to the wire connection; wrong terminal connection will cause malfunction of the product and even damage the product; 3. Don’t dismantle the product, and carry with care to avoiding bump and fall of the product; 4. If the product has been using under the environment with strong magnetic field interference, please pay attention to the shield of input wire, and the output signal wire should be as short as possible. For product intensive installation, the space between each product should not be smaller than 10mm. 5. Only use identified terminals. 6. There is no lightening strike prevention circuit design in this product. For out door and hazardous environment using, please add protective alternatives. 7. This product uses fire prevent ABS crust, its temperature withstand is only limited as +85°C, higher than this limitation will cause the product deformation. Please use and store carefully.

1. The product has compliance with EN50022; suitable for DIN rail mounting NS35/7.5, NS35/15. Installation steps are as following (please reference to dimensional drawing): Step 1: Immobilize one side of product‘s mounting trough to the DIN mounting rail; Step 2: Pull out the spring clasp; Step 3: Place whole mounting trough to the DIN mounting rail properly; Step 4: Release spring clasp to make sure the installation. 2. The product has calibrated before out of factory. After correctly wiring, it can be powered and used immediately. But for further precise signal sampling, user needs to warm-up the product for 3 minutes before use. a) The auxiliary power requires isolation voltage≥2000VAC, DC current output ripple <10mV, and multiple converters can share with one set auxiliary power together. b) Output signal (hz) is designed to follow the impedance load value of 250Ω; When Resistance (R1 ) is less than 100Ω, the user must add output current circuit a power reduced resistance load R0 to keep the summation of total impedance value is between 100Ω~ 250Ω.

3. The Maximum volume of line for the transducer terminal is 2.5mm 2 ; the insulation layer of the line should be peeled off about 8mm~10mm and tightly twisted to connect with the transducer terminals. 4. For the less than 10A AC current measurement, it may adopt ampere-turn method for input and for this time, the resolution of the transducer increases and measuring range narrows, but other technical index may not be affected.

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

21

INCLINOMETER SENSOR

22 SIN01 INCLINOMETER SENSOR Description SIN01 Inclinometer Sensor is a compact dual-axis inclinometer. Adopting the latest technology, with precision engineering from MEMS, this product has low power Consumption. It has excellent consistency and stability. It’s working temperature is -40 °C ~85 °C. A non-contact measurement principle is adopted to simultaneously output the pitch and roll inclination angles. Electrical Characteristic Performance

Technical Specification

Power supply (Unregulated voltage) Operating current (Non-loaded)

9 – 35 V (Typical 12V) 20 - 60 mA (Typical 50mA)

Operating temperature - 40 – +85 °C Sore temperature - 55 – +100 °C

Size (LxWxH)

91×40×26mm

Weight

150g

It can be easily operated and installed without knowing the exact “flat plane”. It has the latest MEMS sensor production technique which is characterized by high accuracy, small size, strong anti-electro-magnetic interference capacity, and great shockproof property. This product is perfect for vehicles and caravans.

Measuring range ± 30°

Measuring axis

X-Y

Zero point output

2.5(5) V

Zero temperature drift (-40°C-85°C)

± 0.01°/°C

Full scale output voltage 0-5V

Sensitivity error (25°C)

± 1%

Frequency response (DC)

100Hz

Output noise density (DC 100Hz)

0.0025

Resolution 0.02°

Accuracy 0.2°

Shock resistance 2000g,0.5m,- 3times/axis

Crossed sensitivity

Max 3%

Electrical Interfaces

Red V In

Grey & Black GND on both

Brown X Out

Orange Y Out

Mechanical Properties Connector

Direct lead (1.5m)

Protection level

IP67

Magnesium Aluminum

Shell material

Installation Four M4 screws

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

23 SI01 INCLINOMETER SENSOR Installation

Keep the sensor installation surface parallel to the measured objective plane during installation. Reduce the impact of motion and acceleration on the sensor. The product can be installed only horizontally.

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

24

PRESSURE SENSOR

25 SPH01 COMPRESSED AIR PRESSURE SENSOR Description Technical Specification

SPH01 Pressure Sensor will measure compressed air, fuel pressure, oil pressure, hydraulic pressure and gas pressure easily. It uses flush ceramic piezo-resistive Technology. The advanced circuit design minimizes the impact of temperature and Humidity. Its pressure chamber is made of 316L stainless steel welted with O-rings to give trouble free leakage. Digital circuits capable of strong RFI & EMI resistance and automatic temperature compensation are installed inside the transmitter and the transmitter is featured with strong interference resistance.

Parameter

Pressure range 0-300psi, Gauge

Measuring medium Compressed air

Signal output

0-5V

Power supply

12V DC

Overload 150%.F.S

Burst pressure 200%F.S

Accuracy (Linearity hysteresis repeatability)

≤ ± 0.5%.F.S

Stability 0.2%F.S ± 0.05%

Working Temperature -30°C~80°C

Storage temperature -40°C~85°C

Zero temperature drift

≤ 0.02%.F.S/°C/year

Net Weight

0.1kg

Piezo-resistive Flush Ceramic

Housing material

304 Stainless Steel

Diaphragm material

Process material

304 Stainless Steel

Medium compatible 304 Stainless Steel

Insulate resistance >100MΩ @50V

Response time ≤10ms

Electronic Wire 3 Wires

Electronic connection Directly sealed cable IP67

Pressure connect port

G1/4”

Cable specs Water Proof

1m PE cable

Certificate approving CE Certificate

IP65

EMC Standard Electromagnetic radiation: EN50081-1/-2 Electromagnetic susceptibility: EN50082-2

Dimension and Drawing (mm)

Electronic Wire Connections

Red Power Supply +

Black Power Supply -

Blue & Green Signal Output +

White/Yellow Signal Output -

Yellow Ground Wire

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

26 SPR01 REFRIGERANT PRESSURE SENSOR Description Technical Specification

SPR01 Pressure Sensor will measure refrigerant Pressure, especially R134(a). It uses flush ceramic piezo-resistive Technology. The advanced circuit design minimizes the impact of temperature and Humidity. Its pressure chamber is made of 316L stainless steel welted with O-rings to give trouble free leakage. Digital circuits capable of strong RFI & EMI resistance and automatic temperature compensation are installed inside the transmitter and the transmitter is featured with strong interference resistance.

Parameter

Pressure range 0-300psi, Gauge

Measuring medium Refrigerant

Signal output

0-5V

Power supply

12V DC

Overload 200%.F.S

Burst pressure 300%F.S

Accuracy (Linearity hysteresis repeatability)

≤ ± 0.5%.F.S

Stability 0.2%F.S ± 0.05%

Working Temperature -40°C~85°C

Storage temperature -40°C~100°C

Zero temperature drift

≤ 0.02%.F.S/°C/year

Net Weight

0.1kg

Piezo-resistive Flush Ceramic

Housing material

304 Stainless Steel

Diaphragm material

Process material

304 Stainless Steel

Medium compatible 304 Stainless Steel

Insulate resistance >100MΩ @50V

Response time ≤10ms

Electronic Wire 3 Wires

Electronic connection Packard 3 Pin Connector

Pressure connect port

G1/4”

Cable specs Water Proof

1m PE cable

Certificate approving CE Certificate

IP67

EMC Standard Electromagnetic radiation: EN50081-1/-2 Electromagnetic susceptibility: EN50082-2

Dimension and Drawing (mm)

Electronic Wire Connections

Red Power Supply +

Black Power Supply -

Blue & Green Signal Output +

White/Yellow Signal Output -

Yellow Ground Wire

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50