Simarine and Sensor Wiring Manual

23

Accessory Main Switch

12V Power To another SiCOM port

SiCOM

S T 10 7

0 - 6 5kOHM

0 - 35V DC

V

V

V

NC NO

COM

COM

11 R 4

R 3

U2

R 2

U1 GND

U3

R 1

12

7

9

10

8

2 1

6

5

4

3

ST107 DIGITAL TANK MODULE

UP TO 3 UNITS

UP TO 3 UNITS

VOLTAGE INPUTS

RESISTANCE INPUTS

0-65 koHM

ONLY Voltage Level Sensor

Resistance Level Sensor

OR

OR

TEMPERATURE SENSOR

BATTERY BANK (Voltage ONLY)

INPUT NTC 10 koHM -15 - 90 °C

DOCUMENT AND CONCEPTS ARE COPYRIGHT SAFIERY PTY LTD THE ITEMS THAT ARE COVERED IN A PACKAGE MAY VARY BECAUSE OF SENSOR AND/OR MODULE CONFIGURATION. V2.1