14 STLWXXX WEMA STYLE TANK LEVEL SENSOR Description Technical Specification
STLW200, STLW400 & STLW450 WEMA Style Sensors for both fuel and water provides highly accurate level measurement for a wide variety of applications, including those in severe environments. Measurement is done using “hall effect” with reed switches positioned inside the level tube. A float with built-in magnets then triggers the reed relays generating a potential - free resistance with an ohm value that increases or decreases. The float is the only moving part of the sensors, thereby minimising potential mechanical failures. All sensors are fully insulated to protect against voltage inside the tank. The level sensors are made of stainless steel and can be mounted in almost any tank shape either by standard 5-hole configuration.
Parameter
200mm, 400mm, 450mm 240-33 Ω
Sensor Size
Measuring medium Fuel,Oil, Water
Signal output
Resolution 21mm
Working Temperature -40°C~85°C
Response time 0.1s
316 Stainless Steel OR 304 Stainlless Steel
Housing material
Mounting method Standard SAE 5 hold pattern
Protection Rank
IP67
Cable specs
50cm PVC cable
Dimension and Drawing (mm)
Instructions
To test correct operation, unscrew fuel sender, connect two wires to multimeter, set to resistance and move float up and down by hand. With float at the bottom it should read 0 ohm and at the top 180 ohm.
COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT
Powered by FlippingBook