Simarine and Sensor Wiring Manual

19 SAC01 AC CURRENT SENSOR Description SAC01 AC Current Sensor provides a calibrated DC output proportional to the AC current input. It is set on a range of 0-30A input AC current. With this sensor, you will see the amount of shore or site power coming in. When set with low alarm, it will signal if you lose AC power input for whatever reason. Designed for multi-point current sensing, it uses classic current isolation and measurement systems. Performance Size (LxWxH) DIN rail

Technical Specification

95×37×88.5 mm 35mm Panel mount

Weight

120g

Aperture Size 20mm

Electrical Parameters Standard application IEC688:1992

Input range 0 - 30A

-10 ~ 50°C,20% -90%,non condensing Storage environment

-40 ~ 70°C,20% -95%,non condensing

Working environment

This device provide excellent ability for anti interference with accuracy of 0.5%. Average RMS is used when sensing current waveforms that have a fixed frequency.

Basic accuracy ≤0.5%.F.S

Calibration RMS calibrated Average sensing Output load 0-5V dc – 2k Ohm

Thermal drift

≤100PPM/°C (0~50°C)

Power consumption ≤30mA+output current

Power source 12V

Isolation voltage ≥100MΩ(DC500V)

Response time

≤300mS

Dimension and Drawing (mm)

Wiring Diagram

COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT