28 SCP01 CABIN PRESSURE SENSOR Description Technical Specification
SCP01 cabin pressure sensor made to be highly accurate with a high stability, pressure sensitive Micro-chip. It has strict precise temperature compensation, linear compensation, signal amplification, V/I conversion, reverse polarity protection, current limiting pressure overload signal Processing. It will operate with very small pressure, flow and other parameters. The transducer is especially suited to measuring cabin pressure in the range of 0-100Pa.
Parameter
Pressure range 0-200pa, Gauge
Measuring medium air
Signal output
0-5V
Power supply
12V DC
Overload 200%.F.S
Burst Pressure 300%F.S
Accuracy (Linearity hysteresis repeatability)
≤ ± 0.5%.F.S
Long stability
0.2%F.S ± 0.05%
Working Temperature -30°C~80°C
Storage temperature -40°C~85°C
Zero temperature drift
0.03%.F.S/°C
FS temperature drift Pressure connect port
0.03%.F.S/°C
Housing material
Alloy
Open
Insulate resistance >100MΩ @100V
Response time ≤4ms
Electronic Wire 3 Wires
Electronic connection Directly cable IP65
IP65 (except air inputs)
Water Proof
Cable specs
1m PE cable
Certificate approving CE Certificate
Water Proof
IP65
Dimension and Drawing (mm)
Electronic Wire Connections
Red Power Supply + Yellow Signal Output + Black Ground & Shield Wire
Green Power Supply - Green Signal Output -
COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT
Powered by FlippingBook