Simarine and Sensor Wiring Manual

29 SCD01 CABIN DUST SENSOR Description SCD01 cabin dust sensor uses laser scattering principle, detecting the existence of dust particle concentration in the Air. The minimum can detect 1.0 um particles with good consistency and stability. Please specify if the range is PM1 or PM2.5 or PM10. Parameter Object Output

Technical Specification

PM1.0, PM2.5, PM10

Range 0-1000ug/m 3

0-5V

Power supply

12V DC

Accuracy ± 3%.F.S@25°C

Power consumption <50mA

Warm up time 3min

Response time <90s

Working Temperature -20°C~50°C @15%-80%RH

Storage temperature -40°C~60°C @20%-90%RH

Temperature drift

≤ 0.2%.F.S/°C

Stability < ± 2%.F.S

Repeatability

<± 1%.F.S

Shell material

ABS

Dimension and Drawing (mm)