29 SCD01 CABIN DUST SENSOR Description SCD01 cabin dust sensor uses laser scattering principle, detecting the existence of dust particle concentration in the Air. The minimum can detect 1.0 um particles with good consistency and stability. Please specify if the range is PM1 or PM2.5 or PM10. Parameter Object Output
Technical Specification
PM1.0, PM2.5, PM10
Range 0-1000ug/m 3
0-5V
Power supply
12V DC
Accuracy ± 3%.F.S@25°C
Power consumption <50mA
Warm up time 3min
Response time <90s
Working Temperature -20°C~50°C @15%-80%RH
Storage temperature -40°C~60°C @20%-90%RH
Temperature drift
≤ 0.2%.F.S/°C
Stability < ± 2%.F.S
Repeatability
<± 1%.F.S
Shell material
ABS
Dimension and Drawing (mm)
COPYRIGHT © SAFIERY PTY LTD ALL CONCEPTS IMAGES AND TEXT IN THIS EBOOK ARE SUBJECT TO COPYRIGHT