Safiery CANbus Alternator Controller

DCV; -- DC-DC ENERGY TRANSFER CONFIGURATION “D CV;, Model, Mode, , Volts, Volts_HalfPower, ,Assist Limit Amps, ,Aug Limit Amps, Aug Limit Volts, Aug Limit SOC ”

Model:

Model of DC-DC Converter configured to support (See $CDD: command)

Mode:

Operational mode of optional DC-DC converter bridging the Primary(Target) and Secondary battery.

2 nd battery Target voltage, above this charge assist mode is enabled.

Voltage:

2 nd battery Target voltage when regulator is in Half-power mode

Volts HalfPower:

Assist Limit Amps: Max current while in primary battery Charge Assist mode.

Aug Limit Amps: Max current while in 2 nd battery augmentation mode.

Aug Limit Volts: Primary battery voltage cutoff, below this 2 nd battery augmentation mode is disabled.

Aug Limit SOC: Primary battery SOC cutoff, below this 2 nd battery augmentation mode is disabled.

Note: DCV: will only be sent if the optional DC-DC converter has been configured, ala the Model is not set = None. (See $CDD: command on page 60 )

16