Safiery CANbus Alternator Controller

CPE; -- CHARGE PROFILE ENTRY In response to RCP: command, this displays the current values of a Charge Profile Entry. Special note on Charge Profile Entries: All voltage and cu rrent values in Charge Profile tables are displayed in their normalized ‘12v’ val ues. See Defining Charging Voltages and Amps for additional information. “CPE;, n, ac ptVBAT, acptTIME, acptEXIT, res1, , ocAMPS, ocTIME, ocVBAT, ocAEXIT, , floatVBAT, floatAMPS, floatTIME, floatRESUMEA, floatRESUMEAH , floatRESUMEV, ,pfTIME, pfRESUME, pfRESUMEAH, , equalVBAT, equalAMPS, equalTIME, equalEXIT, , BatComp, CompMin, MinCharge, MaxCharge, ,RdcVolts, RdcLowTemp, RdcHighTemp, RdcAmps, ,floatSOC, ,MaxAmps, , pfVBAT, ”

n:

Charge Profile ‘n’ is being displayed/returned (1..8)

acptVBAT:

Target battery voltage during BULK and ACCEPT phase

acptTIME:

Time limit to stay in ACCEPT mode – in Minutes.

acptEXIT:

Amp limit to trigger exiting ACCEPT mode

res1:

Reserved for future use (dV/dT exit criteria, currently = 0, disabled)

ocAMPS:

Max Amps which will be supplied by during OVERCHARGE mode.

ocTIME:

Time limit to stay in OVERCHARGE mode – in Minutes.

ocVBAT:

Target battery voltage during OVERCHARGE phase

ocAEXIT:

Amp limit to trigger exiting OVERCHARGE mode

floatVBAT:

Target battery voltage during FLOAT phase

floatAMPS:

Max Amps which will be supplied by during FLOAT mode.

floatTIME:

Time limit to stay in FLOAT mode – in Minutes.

floatRESUMEA: Amp limit to trigger resumption of BULK charge mode

floatRESUMEAH: Amp Hours withdrawn after entering Float to trigger resumption of BULK charge mode

floatRESUMEV: Volt limit to trigger resumption of BULK charge mode

Note: If the regulator is in FORCED_FLOAT mode via the FEATURE-IN pin, then none of the above checks to exit float mode (e.g., floatTIME) will be performed. However, regulation will still occur to floatVBAT and floatAMPS .