pfTIME:

Time limit to stay in POSTFLOAT mode – in Minutes, before resuming FLOAT charge mode.

pfRESUME:

Battery Voltage that will trigger resumption of FLOAT charge mode

pfRESUMEAH: Amp Hours withdrawn after entering Post Float to trigger resumption directly to BULK charge mode

equalVBAT:

Target battery voltage during EQUALIZE phase

equalAMPS:

Current limit of Alternator while in EQUALIZE mode

equalTIME:

Time limit to stay in EQUALIZE mode – in Minutes.

equalEXIT:

Amp limit to trigger exiting EQUALIZE mode

BatComp:

Temperature Compensations value per 1-degree C (normaliz ed to ‘12v’ battery)

CompMin:

Minimum temperate to apply compensation at. In degrees C

MinCharge:

Minimum temperate to charge the battery at, below this will force into FLOAT mode.

MaxCharge:

Maximum temperate to charge the battery at, above this will force into FLOAT mode.

RdcVolts:

Battery low Volts trigger for Reduced Charging

RdcLowTemp: Battery low Temperature trigger for Reduced Charging.

RdcHighTemp: Battery high Temperature trigger for Reduced Charging.

RdcAmps:

Current limit while in Reduced Charging state.

flaotSOC:

SOC level to trigger resumption of BULK charge mode .

MaxAmps:

Maximum battery charge current during any charge phase.

pfVBAT:

Target battery voltage during POST-FLOAT phase