Safiery CANbus Alternator Controller

SST; -- SYSTEM STATUS “SST;, Version , ,Small Alt Mode?, Tach Mode?, , CP index, BC Mult, SysVolts, ,AltCap, CapRPMs, , Ahs, Whs, ,ForcedTM?”

Version:

Firmware revision identifier. Will have format of “AREG” followed w/o a space by the version number. E.g., “AREG1.0.1”

Small Alt?:

0 or 1, has the user selected Small Alternator Mode? (1 = yes)

Tach Mode?

0 or 1, has user selected Tach Mode? (1 = yes)

CP Index:

Which Charge profile (1..8) is currently being used?

BC Mult:

What adjustment factor for Battery Amp Hour Capacity (1-10x) is currently being used? Fractional values may also be used to fine tune the system to a given battery size. This needs to be entered via the $SCO: command.

SysVolt:

Detected system voltage. Adjusts target Charge Profile Volts per the following table:

Detected System Voltage

Charge Profile VOLTAGE Adjustment Factor

SysVolt

1

12v

1x

2

24v

2x

2.67

32v

2.667x

4

48v

4x

Fractional values may also be used to support battery voltages such as 8v, 32v, 42v. Those values will need to be selected manually via the $SCO: command.

Alt Cap:

If regulator is configured to auto-determine the capacity of the alternator, this will be the current high-water mark noted.

CapRPMs:

And this will be the RPMs at which that capacity was noted at.

AHs:

The number of Amp-Hours that have been produced in the current charge cycle.

WHs:

The number of Watt-Hours produced in the current charge cycle.

ForcedTM?:

0 or 1, has user forced Tach-Mode on via the $SCT: command.