Feature-OUT:
<WHOLE NUMBER ( 0 2 )> Modifies the behaviors of the Feature-out port according to the
following table. Applying a modifier will override any other default behavior.
Feature-IN Override
Option
Modified behavior of Feature-IN port
0
Default
Feature-out will remain inactive until the Post-Float phase is reached. Often used to signal generator-stop when a battery if fully charged. The device entering a HARD FAULT will also activate the Feature-out with this option. Caused Feature-out to become active when the battery heater is indicated as being active via CAN. Useful to drive enable pin on external power source for battery heater as BMS indicates a need.
Activate in post Float
1
Battery Heater Active
2
$SCO: will reply with “AOK;” if the command was processed successfully. However, to assure the changes are STORED and used the regulator must be reset using the $RBT: command after all changes have been made.
$SCO: will no longer be recognized once it has been locked-out.
Example - Configure to override DIP switches and positively define system voltage and battery capacity:
If not already done, set regulators name Use CPE#3 (FLA#2 – large batteries)
1500AH battery (BC Index = 3) 12v system (SV Override = 1)
Lockout NOT enabled (Allows continued changes)
$SCN:0,MainsAlt,5555@ $SCO:3,3,1,0,0@ $RBT:@
52