Safiery CANbus Alternator Controller

Feature-OUT:

<WHOLE NUMBER ( 0  2 )> Modifies the behaviors of the Feature-out port according to the

following table. Applying a modifier will override any other default behavior.

Feature-IN Override

Option

Modified behavior of Feature-IN port

0

Default

Feature-out will remain inactive until the Post-Float phase is reached. Often used to signal generator-stop when a battery if fully charged. The device entering a HARD FAULT will also activate the Feature-out with this option. Caused Feature-out to become active when the battery heater is indicated as being active via CAN. Useful to drive enable pin on external power source for battery heater as BMS indicates a need.

Activate in post Float

1

Battery Heater Active

2

$SCO: will reply with “AOK;” if the command was processed successfully. However, to assure the changes are STORED and used the regulator must be reset using the $RBT: command after all changes have been made.

$SCO: will no longer be recognized once it has been locked-out.

Example - Configure to override DIP switches and positively define system voltage and battery capacity:

If not already done, set regulators name Use CPE#3 (FLA#2 – large batteries)

   

1500AH battery (BC Index = 3) 12v system (SV Override = 1)

 Lockout NOT enabled (Allows continued changes)

$SCN:0,MainsAlt,5555@ $SCO:3,3,1,0,0@ $RBT:@