$CDD: - Change parameters in the DC-DC Configuration table
Configure the DC-DC converter for this regulator
$CDD: <Model>, <Mode>, <Volts>, <Volts_HalfPower>, <Assist_Amps_limit>, <Aug_Amps_limit>, <Aug_limitV>, <Aug_limitSOC>
Model : <WHOLE NUMBER ( 0 2 )> Which DC-DC converter is attached?
Value
Brand
Supported Modes
0 1
Not Present (default)
n/a
WS3000r APS12BI58-3000 Safiery Scotty tm
0..3
2
WS3000r-24 Safiery Scotty tm (24v)
0..3
Default = 0 (None)
Mode : <WHOLE NUMBER ( 0 3 )> How should optional DC-DC converter behave?
Value
Mode
0 1 2 3
Off, Disable, Not Present
Charge Assist
2 nd Battery Augment
Dynamic
The WS500 Advanced Alternator Regulator has the ability to manage an optional external DC-DC converter and control the transfer of power between two separate DC busses. In Charge Assist mode the converter is used to direct power from a 2 nd battery/alternator system to assist in meeting the charging goals of the primary battery the WS500 is managing. In 2 nd Battery Augment mode, power is taken from the primary battery/alternator and directed to the 2 nd battery. Dynamic mode intelligently manages between Charge Assist and 2 nd Battery Augment mode, directing power as needed and available.
In each case there is no need for a physical alternator to be attached to the associated batteries.
60