Safiery CANbus Alternator Controller

$CDD: - Change parameters in the DC-DC Configuration table

Configure the DC-DC converter for this regulator

$CDD: <Model>, <Mode>, <Volts>, <Volts_HalfPower>, <Assist_Amps_limit>, <Aug_Amps_limit>, <Aug_limitV>, <Aug_limitSOC>

Model : <WHOLE NUMBER ( 0  2 )> Which DC-DC converter is attached?

Value

Brand

Supported Modes

0 1

Not Present (default)

n/a

WS3000r APS12BI58-3000 Safiery Scotty tm

0..3

2

WS3000r-24 Safiery Scotty tm (24v)

0..3

Default = 0 (None)

Mode : <WHOLE NUMBER ( 0  3 )> How should optional DC-DC converter behave?

Value

Mode

0 1 2 3

Off, Disable, Not Present

Charge Assist

2 nd Battery Augment

Dynamic

The WS500 Advanced Alternator Regulator has the ability to manage an optional external DC-DC converter and control the transfer of power between two separate DC busses. In Charge Assist mode the converter is used to direct power from a 2 nd battery/alternator system to assist in meeting the charging goals of the primary battery the WS500 is managing. In 2 nd Battery Augment mode, power is taken from the primary battery/alternator and directed to the 2 nd battery. Dynamic mode intelligently manages between Charge Assist and 2 nd Battery Augment mode, directing power as needed and available.

In each case there is no need for a physical alternator to be attached to the associated batteries.

60