Scotty AI 1500 Wiring Diagram
GND
Can’t use chassis for Temperature Probe negative. Need to wire it directly to Scotty GND.
Cable marked CAN + is CAN hi for connection to CANbus Cable marked CAN - is CAN hi for connection to CANbus
12V Alternator Sense Wire Need to be 3 amp fused
Use ‘Bat-’ wire as temperature input
24V-48V in
12V
12V only !!! (if you connect HS, it will damage it) Scotty Breaker switch will connect here. Need to be 3 Amp fused
Cable marked “Feature In” is to be used to disable charge from a BMS “stop charge” relay. A high signal allows charger. There is an “inverted” selection in the app for reverse condition wiring.
Cable marked Bat Temp - is used for power supply to Scotty Touch Display as 5V+ Output. If no display, just leave coiled up and reserved.
Scotty AI ver 2.001