7. Troubleshooting If the Caravan Panel is showing wrong sign for current value. Check if the shunts are correctly installed. This means the consumers/generators minus (optionally plus) terminal is connected to the IN terminals on the shunts. If this is not the case, you can reinstall the shunts or simply switch the IN and OUT terminal via the shunt configuration on the Caravan Panel. 7.1 Shunt Sensors not visible

If the shunt sensor is not visible in the Caravan Panel menu, check the following:

· Is the Caravan Panel properly connected to the SiCOM PANEL port (Third port on SPDU-52)? If you are using your own SiCOM cable, make sure it has the right square and is twisted. · Is the Inclinometer module connected properly to SiCOM port 1 or 2 on the SPDU-52 or directly to the Caravan Panel?