Safiery Sensors and GX Tank 140 - User Manual

Safiery LPG Tank Sensor T his sensor attaches magnetically under an LPG tank. It uses ultrasonic principles so therefore requires a sealed interface between the sensor and the tank shell. Excessive paint or rough surface will void operation. When operating successfully, the sensor flashes "blue" LED at the sensor itself. A gel couplant is included with the sensor. Whilst this sensor iappears similar to the water tank sensor, the actual ultrasonic head is not. It is a more powerfull ultrasonic to penetrate the thicker propane tanks and requires a digital pre-processor to convert back to 0-5V output. This is a 12V powered sensor.

Technical Specification for Sensor. Pre-processor is IP22

Performance Recommended application LPG Tank IP67

Measurement mode Non-contact

Length of wire 2000mm

Size (LxWxH)

50x50x20mm

Work temperature - 15 – +60 °

Storage temperature - 25 – +8 °C

Electrical Parameters

Working voltage 12 V DC

Average current

<25mA

Blind zone ≤50mm

Measuring height of LPG level

50-1,000mm

Response time (with water)

2s

Accuracy(normal temperature) ± 4%

Output mode Analog voltage

Resolution 1mm

Center frequency 2mHz

ESD ±4/±8KV

LED indicator light instructions

Slow flash LED flashes every second for valid couplant engagement

The Relational Graph Between Distance

Powered by