S ENDING DATA TO THE REGULATOR : All commands begin with the character ` $’, contain 3 letters(CAPS) followed by a ` :’ and then parameters as requested by the command. All must end with a CR (or CR/LF) or may optional be terminated with the character `@ ’. A complete ‘string’ must be received within 60 seconds from the `$’ to the ending `@’/CR/LF, else the regulator will abort the capture of that string and begin looking for a new ` $’ starting character.
Sending data TO the regulator:
27
$CPA:n - Change ACCEPT parameters in CPE user entry n (n = 7 or 8)
29
$CPO:n - Change OVERCHARGE parameters in CPE user entry n (n = 7 or 8)
30
$CPF:n - Change FLOAT parameters in CPE user entry n (n = 7 or 8)
31
$CPP:n - Change POST-FLOAT parameters in CPE user entry n (n = 7 or 8)
33
$CPE:n - Change EQUALIZE parameters in CPE user entry n (n = 7 or 8)
34
$CPB:n - Change BATTERY parameters in CPE user entry n (n = 7 or 8)
35
$CPR:n - RESTORES Charge Profile ‘n’ to default values
36
$DEP: - DEPendency
37
$RAS: - Request All Status back
38
$RCP:0 - Request to send back currently selected CPE
39
$RLF: - Request Last Fault
40
$SCA: - Changes ALTERNATOR (and System) parameters
41
$SCT: - Changes TACHOMETER parameters
48
$SCO: - Override features
50
$SCN: - Changes NAME (and PASSWORD)
53
$SCR: - RESTORES System Configuration table to default
54
$CCN: - Change parameters in the CAN Configuration table
55
$CDD: - Change parameters in the DC-DC Configuration table
60
$CCR: - RESTORES CAN Configuration to default
64