Safiery CANbus Alternator Controller

$CCR: - RESTORES CAN Configuration to default

Restores CAN Configuration values to original as-compiled (default).

$CCR: will reply with “AOK;” if the command was processed successfully. However, to assure the changes are STORED and used the regulator must be reset using the $RBT: command after all changes have been made.

$CCR: will not be recognized if system has been locked-out via the $SCO: command.

$MSR: - RESTORE all parameters to factory default.

Restores all configurable parameters to the factory default values. This is a combination of the $SCR: , $CCR commands, the $CPR:n commands for all Charge Profile Entry tables, and $RBT; command. Alternator will RESET after this command is completed.

$MSR: <Password>

Note $MSR is disabled if the Regulator has been locked out via the $SCO command. If successful, the regulator will reply with “AOK;” and then reboot.

Password:

<STRING (up to 18 characters, no spaces, comma, or ‘@’) > Optional Password may be supplied

to clear a level 1 lockout.

$MSR: will not be recognized if system has been locked-out (level 1) via the $SCO: command unless the correct devices password is supplied. Note that a lockout level 2 is not clearable, even if the correct password is supplied.

64