Black Bridge Control Panel

S I M A R I N E ®

Black Bridge Control Panel

USERS MANUAL

V1.0

Table of contents 1. Introduction .......................................................................... 3 2. Safety .................................................................................... 3 3. Overview .............................................................................. 4 4. Installation ............................................................................ 4 4.1 Mounting ........................................................................................................... 4 4.2 Cables ................................................................................................................. 5 4.3 SICOM Panels ..................................................................................................... 5 4.4 Resistance & Voltage Inputs ............................................................................. 6 4.5 4 Stage Level 1 & 2 ............................................................................................. 6 4.6 Batteries, Chargers, Ground, Main Switch ....................................................... 7 4.7 Relays, Inputs ..................................................................................................... 8 5. Connecting ............................................................................ 8 5.1 Diagram .............................................................................................................. 9 6. Technical specifications ...................................................... 10 7. Troubleshooting ................................................................. 11 7.1 Shunt Sensors not visible ................................................................................ 11

2

1. Introduction Simarine SPDU-52 power distribution unit is a very versatile module. It's purpose is to power other modules and shunts, which are used by the Caravan Panel. The SPDU-52 has 3 SICOM ports, two for additional power outputs input/outputs (SICOM 1, SICOM 2) and one for the Caravan Panel (SiCOM PANEL). The SPDU-52 has two batteries (main and starter Battery), the voltage output is 8–22 VDC, and the temperature range is from –10 to +70°C (from +10 to +160°F). SPDU-52 also has 4 channels (Solar, Charger, Main battery, Starter battery) that measure current. The accuracy is ± 2%. The voltage measuring on any of these channels is 0–35 VDC with an accuracy of ±0,5%. The resistance measuring on any of these channels is 0–65kohm with an accuracy of ±3%. The SPDU-52 with additional modules can connect up to 6 batteries, 24 shunts, 10 temperature sensors, 14 tank level sensors, 2 inclinometer sensors. 2. Safety Only qualified electricians with proper safety equipment should make installation of Simarine electronics. When working with batteries, you should wear protective clothing and eye protection. CAUTION: Batteries contain acid, a corrosive, colorless liquid that can burn your eyes, skin, and clothing. Should the acid come in contact with eyes, skin, or clothing, wash it immediately under fresh water for at least 15 minutes and seek medical support immediately. CAUTION: Do NOT connect anything to a damaged battery. It could heat up, catch fire, or explode. CAUTION: Lead-acid batteries can generate explosive gases during operation. Never smoke, allow flames, or sparks near the battery. Make sure to keep sufficient ventilation around the battery. CAUTION: When working with a battery, remove all personal metal items like watches, rings, necklaces, and bracelets. Metal items in contact with the battery terminals might cause a short circuit with a very high electric current, which may heat up and melt nearby objects and cause severe burns.

3

Overview

3.

A - 2 SiCom, 1 SiCOM Panel

B - resistance inputs

C - voltage inputs

D - 4 stage level 2

E - 4 stage level 1

F - main and starter battery

G - manual main switch

H - solar charger

I - charger

J - inputs and outputs

K - common ground

Installation

4.

4.1 Mounting

CAUTION: Install the power unit in a clean and dry place protected from accidental spilling of liquids. Remove the shunt cover by unscrewing two screws on top of the power unit cover. To install the power unit using supplied voltage cables find a place no further than 3 m away from the battery/battery bank. You can fix the power unit with the supplied screws using four holes (two on each side) on bottom of the casing.

4

4.2 Cables

CAUTION: Failure to observe the required cable cross-sections can damage the shunt, wiring, or cause a fire.

SiCOM data cable: · For the SiCOM connection use the supplied cable.

Cable length C Cable length

Cable type No limitations

< 5m >= 5m

2x2x0.25 mm2 twisted pair (recommended)

4.3 SICOM Panels

A - SiCOM1 port, used for an optional power input (e.g. extra port to connect a SIMARINE module).

B - SiCOM2 port, used for an optional power input.

C - SiCOM PANEL port, used to connect to Black bridge Display Panel

5

4.4 Resistance & Voltage Inputs

A - Resistance inputs, the cable arrangement doesn't matter, because the cable used here is black (the black cable goes to R and GND). The resistance inputs are for potential connections that are resistance based (e.g. tanks, freezer, etc.).

B - Voltage inputs, used for user sensors. Voltage range is from 0 to 75V (the red cable goes to U4 and U3, the black cable goes to GND).

4.5 4 Stage Level 1 & 2

A – 4 stage level 1, all sensors are connected to base and individual sensors to the

6

25%, 50%, 75%, and 100% input. The NC stands for "not connected", meaning it doesn't require an input.

B – 4 stage level 2, the same as the 4 stage level 1 sensor, sensors connected to base and individual sensors to the 25%, 50%, 75%, and 100% input.

Cables: Red goes to the base input, black goes to the rest of the inputs (25%, 50%, 75%, 100%).

4.6 Batteries, Chargers, Ground, Main Switch

A - starter battery B – main battery – has the same current as the solar panel, charger. C – charger – connect to the main battery and main ground (GND). The charger has the same current as the solar panel and the main battery. D – solar charger. E – ground – connect each module that requires to be grounded to the GND. F - Manual main switch, turn the power of the SPDU-52 ON or OFF.

Note: Charger, solar panel and main battery all have the same current.

Nominal Current Limits Continuous

Solar Current Limit

0–25A 0–50A

240V AC charger Current Limit Main battery Current Loads Limit

0–100A DC to DC from starter battery Current Limit 0–50A

0– 3 00A using additional SC301/3/5

Inverter/ High Power DC/DC Current Limit

Accuracy

±2%

Sample rate

100ms

7

4.7 Relays, Inputs

A - Relays K1-K6 The configuration for the functionality of the K1–K6 buttons can be changed in the program. The default settings however, are the following: · K1 - Fridge · K2 - Heating · K3 - AC · K4 - Aux · K5 - Water pump · K6 - Lighting Relays are open to configuration Button Labels are Custom Engraved by Safiery UNDERNEATH each button Buttons are BLANK

B - Connections

C - Connection inputs and outputs

5. Connecting The Caravan Panel must be connected to the third port on the SPDU-52 (SICOM PANEL) or it will not work. If you have an Inclinometer module you can connect it directly to the second port of the Caravan Panel or you can connect the module to SiCOM port 1 or SiCOM port 2. Resistance inputs can be used to connect the temperature sensor, resistance tank sensor, the 4 stage level tank, any resistance based sensor, etc. Auxiliary voltage input, can be used to connect any sensor that outputs voltage.

8

4 stage level 1 & 2, each pin is connected to a percentage mark (25%, 50%, 75%) and one is connected to base input for power. The NC in the 4 stage level 1 stands for "not connected" and does not require an input. Starter & main battery must be connected to the ground on the SPDU-52 (black cable connected to GND). Charger and solar charger both have to be connected to the main battery and common ground (GND on SPDU-52). F1–F12 are connected to any external devices. · For example, F1 and F2 ports are connected to the main battery. F3 connects to the heating and so on. (You can find the information of all relay connections on the physical cover of the SPDU-52 or under the Diagram section)

5.1 Diagram

9

Safiery Guide for 4WD Canopy or Caravan / Motorhome 9 Fused Terminals with 6 Switches Custom Engraved Labels For each Switch circuit, there is a Dedicated Manual Relay Switch on Control Unit Fuse Fuse Size Fuse Size White Canopy Lights DS 10A PS 10A Amber Canopy Lights DS 5A PS 5A

Additional Switch One Outlet

20A

Travel Buddy Oven

15A

Water Pump

15A

Additional Switch Two Outlets

5A

5A

3 Un-switched Circuits with 3 Fused Teminals “Black Bridge Terminal Expansion Pack” uses same wiring plug terminations inside control case. Fuse Fuse Size Fridge 1 10A

Fridge 2

10A

USB Outlets

10A

1 Inverter switched Circuits - no fuse needed

Inverter Switch Best Practice: Middle Switch is Inverter on/off - easy to turn on/off while accessing GPO

Dedicated Switch to Optional Inclinometer - no fuse needed

Inclinometer shows Pitch and Roll which is ideal if using a Roof Top tent

Dedicated Master on/off Switch - no fuse needed

Master On/Off Switch Dedicated Button

Master Backup On/Off Switch Dedicated Manual Relay Switch on Control Unit

Technical specifications

6.

SPDU-52

Operating Voltage range Main battery Starter battery

8–22VDC 8–22VDC

Temperature range

F)

Power consumption at 12V Operating

15mA

Power off

0,25mA

Current measuring Channel 1 (solar) Channel 2 (charger)

0–25A 0–50A 0–100A 0–50A

Channel 3 (main battery) Channel 4 (starter battery)

Accuracy Resolution Sample rate

±2%

±0.1 A 100ms

Voltage measuring on any channel Range

0–35VDC

Accuracy Resolution

±0,5% 10mV

Resistance measuring on any channel Range

0–65kohm

Accuracy Resolution

±3%

1ohm

Temperature measuring (on resistance inputs) Temperature sensor

NTC 5K

Range

From -15 to +80 °C (from +10 to +160° F)

Resolution

3%

Maximum continuous current for output channels K1

20A 20A 15A 15A 10A 10A 50A 20A 40A 20A

K2 K3 K4 K5 K6

All channels simultaneously

Contact continuous current rating Outputs F1–F12

Charger

Solar

Dimensions (without connector) SPDU-52

200 x 160 x 42 mm 7,87 x 6,3 x 1,65in 157 x 82 x 25 mm 6.18 x 3.23 x 0.22in

Caravan Panel

System capabilities (with additional modules) Up to

10

Batteries

6

Shunts

24

Temperature sensors Tank level sensors Inclinometer sensors Smartphone application

10 14

2

1

Logger capacity

up to 3 years

7. Troubleshooting If the Caravan Panel is showing wrong sign for current value. Check if the shunts are correctly installed. This means the consumers/generators minus (optionally plus) terminal is connected to the IN terminals on the shunts. If this is not the case, you can reinstall the shunts or simply switch the IN and OUT terminal via the shunt configuration on the Caravan Panel. 7.1 Shunt Sensors not visible

If the shunt sensor is not visible in the Caravan Panel menu, check the following:

· Is the Caravan Panel properly connected to the SiCOM PANEL port (Third port on SPDU-52)? If you are using your own SiCOM cable, make sure it has the right square and is twisted. · Is the Inclinometer module connected properly to SiCOM port 1 or 2 on the SPDU-52 or directly to the Caravan Panel?

11

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13